BlackDiamond 10808 Series
10±â°¡ºñÆ®
ÀÌ´õ³ÝÀ» À§ÇÏ¿© öÀúÇÏ°Ô ¼³°èµÈ, BlackDiamond 10808 ´Â º¸¾È,À̿뼺,¼öÇà¿¡¼ ÁÖ¿ä±â¼úÀ» ÅëÇÕÇÏ¿´´Ù.
Extreme Networks® ´Â Áö´ÉÀûÀÎ core¿Í ¸ðµç ¸ðµâ·¯ ÀÌ´õ³Ý ½ºÀ§Ä¡°¡ ÃøÁ¤µÉ µ¥ÀÌÅͼ¾ÅÍÀÇ Ç¥ÁØÀÌ
µÇ¾ú´Ù.
BlackDiamond 10808 ´Â Æø³ÐÀº ÇÁ·ÎÅäÄÝÀÇ ¹è¿À» Áö¿øÇÑ´Ù.
µ¡ºÙ¿©¼, BlackDiamond 10808´Â ÇÁ·Î±×·¥ÀÌ °¡´ÉÇÑ ASIC technology¸¦ ÅëÇÕÇÏ¿´´Ù.
ÀÌ ÇÁ·Î±×·¥ ´É·ÂÀº Ç÷§ÆûÀÌ ºñ¿ëÀÌ µå´Â Çϵå¿þ¾î ¾÷±×·¹ÀÌµå ¾øÀÌ »õ·Î ÃâÇöÇÏ´Â ÇÁ·ÎÅäÄÝÀ» Áö¿øÇÒ°ÍÀ» È®½ÅÇÑ´Ù.
ÀÌµé ¾îÇø®ÄÉÀ̼ÇÀº °í¼öÇà,
È®À强, °í¼öÁØÀÇ Åº·Â¼ºÀ» ¿ä±¸ÇÑ´Ù.
´õ¿í Áß¿äÇÑ°ÍÀº, BlackDiamond 10808 ´Â ¿À´Ã³¯ »Ó¸¸¾Æ´Ï¶ó Â÷¼¼´ë¸¦ ÃÊÁ¡À¸·Î ¼³°èµÇ¾ú´Ù.
È®À强Àº Â÷¼¼´ë¿¡ º¯ÈÇÏ´Â ¿ä±¸»çÇ×À» äÅðú ÀÀ´ëÇÒ¼ö ÀÖ´Â Áö´ÉÀûÀÎ core ³×Æ®¿öÅ©¸¦ ±¸ÃàÇϱâÀ§ÇÑ Æ÷ÀÎÆ®´Ù.
ÀÌ°ÍÀº
BlackDiamond 10800°¡ ¿Ö ŸÀÇÃßÁ¾À» ºÒÇãÇÏ´ÂÁö ¸»ÇØÁÖ´Â ÀÌÀ¯ÀÌ´Ù.
|
|
Target Applications
BlackDiamond 10808 ´Â ¾îÇø®ÄÉÀ̼ÇÀÇ ´Ù¾çÇÑ ¹è¿¿¡¼ ¿ì¼öÇϵµ·Ï
¼³°èµÇ¾ú´Ù.
- ÁýÇÕ³×Æ®¿öÅ©¸¦ À§ÇÑ ±â¾÷ ¹éº»½ºÀ§Ä¡
- mission critical ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ¼¹ö »óÈ£¿¬°áÀ» Á¦°øÇÏ´Â
±â¾÷µ¥ÀÌÅͼ¾ÅÍ ½ºÀ§Ä¡
- Triple play ¼ºñ½º¸¦ Àü´ÞÇÏ´Â ¸ÞÆ®·Î ÄÚ¾î¿Í ¹èÄ¡¸¦ À§ÇÑ ½ºÀ§Ä¡
- °í´ë¿ªÆø Layer 2 »óÈ£¿¬°áÀ» Á¦°øÇÏ´Â ÀÎÅÍ³Ý ±³·ù¸¦ À§ÇÑ ½ºÀ§Ä¡
- º¹ÀâÇÑ Computing(°è»ê) ¹®Á¦¸¦ À§ÇÑ ¼Ö·ç¼ÇÀ» Àü´ÞÇÏ´Â °í¼öÇà Ŭ·¯½ºÅÍ
ComputingÀ» À§ÇÑ »óÈ£¿¬°á ½ºÀ§Ä¡
Security
- CLEAR-Flow Security Rules EngineÀÇ Ä§ÀÔŽÁö¿Í ÀÀ´ë
- Layer 3 virtual switching
- °ÈµÈ ³×Æ®¿öÅ© ÀÎÇÁ¶ó
Voice-Class Availability
- Redundant hardware design
- Modular operating system for non-stop operation with ExtremeXOS¢â
Operating System (OS)
- ÀÌ´õ³Ý ÀÚµ¿¹æ¾î ½ºÀ§Äª(EAPS)À» ÀÌ¿ëÇÏ´Â °íÀ̿뼺 ³×Æ®¿öÅ©
Scalable Performance
- System scalability with large table sizes, port capacity
- ¾îÇø®ÄÉÀÌ¼Ç È®À强À» Á¦°øÇÏ´Â Qos¿Í ¸ÖƼij½ºÆ® ¼öÇà
- È®À强À» ÅëÇÑ ÃøÁ¤°¡´ÉÇÑ °ü¸®
Security
BlackDiamond 10808 ´Â ÀÌ´õ³Ý core ³×Æ®¿öÅ·À» À§ÇÑ º¸¾ÈÀÇ »õ·Î¿î
·¹º§À» Àü´ÞÇÑ´Ù.
BlackDiamond 10808 ÇöÀç º¸È£µÇÁö¾Ê´Â ³×Æ®¿öÅ©ÀÇ soft interior
¸¦ º¸È£ÇÔÀ¸·Î½á perimeter firewallÀ» ÀÌÇàÇÑ´Ù.
»ê¾÷¿¡¼ °¡Àå ÁøÈµÈ CLEAR-Flow Security Rules EngineÀ» ÀÌ¿ëÇÔÀ¸·Î½á,
´Ü½Ã°£¸¸¿¡ ħÀÔÀ§ÇùÀ» ÀÚµ¿ÀûÀ¸·Î ŽÁö¿Í
¿ÏÈÇϱâ À§ÇÏ¿© ÇÁ·Î±×·¥
µÉ¼öµµÀÖ´Ù.
Threat Detection and Response
CLEAR-Flow Security Rules Engine
CLEAR-Flow Security Rules Engine Àº ³×Æ®¿öÅ©»óÀÇ ¼ö»óÇÑ Æ®·¡ÇÈÀÇ
´õ¸¹Àº ºÐ¼®À» À§ÇØ °¡»óÈµÈ º¸¾È ¸®¼Ò½º(VSRs)¸¦ À§ÇÑ
first
order ħÀÔŽÁö, °æ°¨ ±×¸®°í mirror Æ®·¡ÇÈÀ» Á¦°øÇÑ´Ù. VSRs ´Â ESF¿¡¼ ¸¶Áö¸· ºÎºÐÀÌ´Ù.
VSRs ´Â Àüü ´Ù¼ö ±â°¡ºñÆ® ³×Æ®¿öÅ©¸¦ °¡»óÀ¸·Î ÀÌ¿ë°¡´ÉÇÏ´Ù.
±×·¯¹Ç·Î º¸¾È ¼Ö·ç¼ÇÀÇ ºñ¿ëÀý°¨ÀûÀÎ È®À强À» °¡´ÉÇÏ°ÔÇÑ´Ù.
Sentriant¢â Àº BlackDiamond 10808 ½ºÀ§Ä¡ÀÇ CLEAR-Flow rule °ú
Ãß°¡µÇ´Â Æ®·¡ÇÈ Ãß°¡³ª ½ÃÀÛÁ¡ Ž»ö º¯È¸¦ À§ÇØ Á¢±ÙÁ¦¾î ¸ñ·Ï
(ACLs)À»
Ãß°¡/¼öÁ¤ÀÌ °¡´ÉÇÏ´Ù. ±×·¯¹Ç·Î ½Ç½Ã°£À¸·Î fine-grain inspection
rules À» À§ÇÑ automated system À» Çã¿ëÇÑ´Ù.
Port Mirroring
ħÀÔŽÁö¿Í ¿¹¹æÀ» Áö¿øÇϹǷÎ, BlackDiamond 10808 ´Â many-to-one
°ú cross module port mirroringÀ» Áö¿øÇÑ´Ù.
³×Æ®¿öÅ© °ø°Ý¿¡ ´ëÀÀÇÒ¶§ Áø´ÜÅø·Î½á °æÇâºÐ¼®À̳ª ³×Æ®¿öÅ© °ü¸®ÀÚ¿¡
ÀÇÇØ È°¿ëµÇ±â À§ÇÑ Ä§ÀÓŽÁö ÀåÄ¡¿Í °°Àº ¿ÜºÎ ³×Æ®¿öÅ© Àåºñ¸¦
À§ÇÑ
Æ®·¡ÇÈ mirror¸¦ À§ÇØ »ç¿ëµÉ¼öÀÖ´Ù.
Line-Rate Access Control Lists
ACLs ´Â ³×Æ®¿öÅ© º¸¾È°ú ¹æ¾î ±×¸®°í ³×Æ®¿öÅ© ¸®¼Ò½º È°¿ëÀ» Á¦¾îÇϱâ
À§ÇÑ °¡Àå °·ÂÇÑ ÅøÁõÀÇ ÇϳªÀÌ´Ù.
BlackDiamond 10808 ´Â Layer 2, 3 ±â¹ÝÀÇ 128K ACLs ³ª MAC address
ȤÀº IP source/destination address ¿Í °°Àº
4- header information
À» Áö¿øÇÑ´Ù.
Virtual Router
Layer 3 °¡»ó ½ºÀ§ÄªÀ¸·Î, BlackDiamond´Â ´Ù¼ö·¹ÀÌ¾î ½ºÀ§ÄªÀ»
À§ÇÑ °¡»óÈÀÇ °³³äÀ» °¡Á®´ÙÁØ´Ù.
Layer 3 °¡»ó ½ºÀ§ÄªÀº ´ÜÀϽºÀ§Ä¡¸¦ ´Ù¼öÀÇ °¡»ó ¶ó¿ìÅÍ·Î ºÐÇÒÀ»
Çã¿ëÇÑ´Ù.
°¡»ó ¶ó¿ìÅÍ´Â ´ÜÀÏ ¹°¸®Àû ¶ó¿ìÅÍ°¡ ÇØ¿Ô´ø°Í°ú °°Àº ´É·Â°ú ¼Ó¼ºÀ»
°¡Áö°íÀÖ´Ù.
ÀÌ°ÍÀº ȯ°æ¼³Á¤, ¿î¿ë ±×¸®°í ¹®Á¦ÇØ°áÀ» À§ÇØ ¸ðµç °°Àº ¶ó¿ìÆÃ
¸ÞÄ«´ÏÁòÀ» »ó¼ÓÇÑ´Ù.
ÀÌ°ÍÀÇ °á°ú·Î½á, °¢±â °¡»ó ½ºÀ§Ä¡ µµ¸ÞÀÎÀº ºÐ¸®µÇ¾î ´Ù·ç¾îÁö¸ç
º¸¾ÈÀ» À§ÇØ °í¸³½ÃÄ×´Ù.
³×Æ®¿öÅ© Æ®·¡ÇÈÀº ¶ÇÇÑ º¸¾ÈÀ§ÇùÀ» ÃÖ¼ÒÈÇϱâ À§ÇØ ºÐ¸®µÈ °¡»óµµ¸ÞÀÎÀ¸·Î
°í¸³µÉ¼öÀÖ´Ù.
°¡»ó½ºÀ§Ä¡ µµ¸ÞÀÎÀÇ ¼³°è´Â ¶ó¿ìÅÍ Å×À̺íÀÇ ³í¸®Àû ºÐÇÒÀ» °¡´ÉÇÏ°ÔÇÑ´Ù.
Multiple ¶ó¿ìÅÍ Å×À̺íÀº ¶ó¿ìÅÍ °í¸³ÀÌ °¡´ÉÇϸç, ¿î¿µÀÚ°¡ overlapping
IP address space ÀÇ ÀÌ¿ëÀ» ÇÒ¼öÀÖ°Ô ÇØÁØ´Ù.
Overlapping IP address spaces ´Â ´ÜÀÏ ¹°¸®Àû ³×Æ®¿öÅ· ÀÎÇÁ¶ó¸¦
°øÀ¯ÇϱâÀ§ÇÑ ´Ù¼ö community¸¦ Çã¿ëÇÑ´Ù.
Hardened Network Infrastructure
Denial of Service Protection
BlackDiamond 10808 ´Â Denial of Service (DoS) °ø°ÝÀ» ÈǸ¢ÇÏ°Ô
´Ù·é´Ù.
¸¸¾à cpu ÀÔ·Â ´ë±â¿¿¡¼ ºñÁ¤»óÀûÀ¸·Î ¸¹Àº ÆÐŶÀÇ ¼ö¸¦ °¨ÁöÇÑ´Ù¸é,
CPU µµ´Þ·ÎºÎÅÍ À̵é ÆÐŶÀ» ÀÚµ¿ÀûÀ¸·Î ¸ØÃß´Â ACLs¸¦
¼ÒÁýÇÒ
°ÍÀÌ´Ù. ¾ó¸¶ÈÄ¿¡, ACLs´Â Á¦°ÅµÇ¸ç, °ø°ÝÀÌ °è¼ÓµÈ´Ù¸é, ´Ù½Ã ¼³Ä¡µÈ´Ù.
ASIC-based Longest Prefix Match
Longest Prefix Match (LPM) routing Àº »õ·Î¿î È帧À» ¹è¿ì±â À§ÇÑ
control plane software ÀÇ Çʿ伺À» °æ°¨½ÃÅ°¸ç DoS °ø°Ý¾Æ·¡ÀÇ
ź·Â¼ºÀ»
À§ÇÑ ³×Æ®¿öÅ©¸¦ Çã¿ëÇÑ´Ù. LPMÀ¸·Î ÀÎÇؼ CPU´Â ¾î¶°ÇÑ ½ÂÀεÇÁö¾ÊÀº ¸ñÀûÁö¸¦ ÇâÇÑ First
PacketÀÇ È帧¿¡ ºÎ´ãÀ»¹ÞÁö
¾ÊÀ¸¸ç, Áß´ëÇÑ ÀÛ¾÷¿¡ ¿µÇâÀ» ¹ÞÁö
¾Ê´Â´Ù.
Secure Management
BlackDiamond 10808 ½Ã¸®Áî¿¡ ÀÇÇØ Áö¿øµÇ´Â SSH2, SCP ¿Í SNMPv3
°°Àº ÇÁ·ÎÅäÄÝÀÇ ÀÌ¿ëÀ¸·Î °ü¸®¿î¿ë°ú
man-in-the-middle attackÀÇ ¹æÇظ¦
¿¹¹æÇÑ´Ù.
MD5 Authentication of Routing Protocols
¶ó¿ìÆà ÇÁ·ÎÅäÄÝÀÇ MD5 ½ÂÀÎÀº °ø°ÝÀÚ°¡ À¯È¿¸Þ½ÃÁö º¯°æ°ú ¶ó¿ìÆÃ
¼¼¼ÇÀ» °ø°ÝÇϴ°ÍÀ» Â÷´ÜÇÑ´Ù.
Automated Attack Mitigation
- °¨¿°µÈ source ³×Æ®¿öÅ© ÀÔ¼º
- BlackDiamond 10808 static ACLs ¿Í CLEAR-Flow rule Àº DoS °ø°ÝÀ» °É·¯³»°í,
¼ö»óÇÑ Æ®·¡ÇÈÀ¸·Î °£ÁÖÇÑ´Ù.
- »ó¼¼ÇÑ ºÐ¼®À» À§ÇÑ Sentriant ÇâÇÑ ¼±ÅÃÀûÀÎ port-mirror traffic
- Sentriant ´Â ¼ö»óÇÑ Æ®·¡ÇÈ °¨½Ã¸¦ °è¼ÓÀûÀ¸·Î ÇÏ¸ç °æ¹ÌÇÔºÎÅÍ À§Çè´Ü°è±îÁöÀÇ Æ®·¡ÇÈ µî±ÞÀ» È®´ëÇϱâ À§ÇÑ
³»ºÎ±ÔÁ¤À» ÀÌ¿ëÇÑ´Ù.
- Sentriant ´Â BlackDiamond 10808 ¿¡ÀÖ´Â ´ÙÀ̳ª¹Í ACLÀ» ½ÃÀÛÇÑ´Ù.
- BlackDiamond 10808 ´Â ½Ç½Ã°£À¸·Î dynamic ACL À» Àû¿ëÇÏ¸ç ¼ö»óÇÑ Æ®·¡ÇÈÀÇ port mirror
¸¦ °è¼ÓÇÑ´Ù.
- Sentriant also sends the mitigation action to Extreme Networks'
EPICenter® network management software.
- EPICenter ´Â º¸¾ÈÁ¤Ã¥À» °ÈÇϱâ(mitigation action) À§ÇØ Áß¾Ó°ú ÇϴܽºÀ§Ä¡¿Í Çù·ÂÇÏ¿© ÀÛµ¿ÇÑ´Ù.
|
|
Voice-Class Availability
°í¼öÇà ³×Æ®¿öÅ© ¿¬°á·Î½á, Á¢¼Ó ·¹À̾¼ PC¿¬°áÀ̳ª IP telephone
¿¬°á¿¡ »ó°ü¾øÀÌ ÀÌ¿ëµÇ¾î ¿ÔÀ¸¸ç
ȤÀº Ŭ·¯½ºÅÍ¿¡¼ »óÈ£¿¬°á ¼¹ö¸¦ À§Çؼµµ ÀÌ¿ëµÇ¾ú´Ù.
BlackDiamond 10808 ´Â ½ºÀ§Ä¡ ¼ºñ½º Áß´Ü ¾øÀÌ ¾÷±×·¹À̵带 À§ÇØ
¸ðµç active component¸¦(OSÆ÷ÇÔ) Çã¿ëÇÑ´Ù.
BlackDiamond 10808 ´Â ¶ÇÇÑ ½ºÀ§Ä¡ÀÇ À̿뼺À» Çâ»ó½ÃÅ°´Â industry
leading ExtremeXOS modular operating system À» ÀÌ¿ëÇÑ´Ù.
Network
level ź·Â¼º ÇÁ·ÎÅäÄÝÀº ³×Æ®¿öÅ©ÀÇ Åº·Â¼º Çâ»óÀ» À§ÇØ Ãß°¡µÇ¾ú´Ù.
Redundant Hardware Design
Redundant Management Modules
BlackDiamond 10808 ´Â hitless ´ëüÀÛµ¿ ¸ÞÄ«´ÏÁò À¸·Î ±¸¼ºµÇ¾î
ÀÖÀ¸¸ç,
°ü¸®½ºÀ§Ä¡ ¸ðµâÀÌ(MSM) ÀÛµ¿ºÒ´ÉÀÌ µÈ´Ù¸é, second MSM ÀÌ Àüü½ºÀ§Ä¡¸¦
À§ÇØ ÀÚµ¿ÀûÀ¸·Î °ü¸®Ã¥ÀÓÀ» Àμö¹ÞÀ»°ÍÀÌ´Ù.
ÀÌƯ¡Àº ¿î¿µÁßÀÎ À½¼º°ú ´Ù¸¥ Áß´ë ¾îÇø®ÄÉÀ̼ǿ¡ ÇʼöÀûÀÌ´Ù.
Advanced Chassis Design for Availability
BlackDiamond 10808 ´Â °í¸³Á¦¾î¿Í data plane °°Àº °íÀ̿뼺 ¼³°è
¿ä¼Ò¿¡ ÀÇÇØ º¸ÃæµÇ¾îÁö´Â passive backplane°ú
ÆÄ¿öºÐ¹è¸¦ À§ÇÑ ÃæºÐÇÑ ÄÁÆ®·Ñ·¯ º¸µå¿Í fan control, ³×Æ®¿öÅ©¿¡
¿µÇâÀ» ÁÖ±âÀü¿¡ ¾Ç¿µÇâÀ» ½Äº°Çϱâ À§ÇÑ È¯°æ ¸ð´ÏÅ͸µÀ» Æ÷ÇÔÇÑ´Ù.
Redundant Load Sharing Power Supplies
BlackDiamond 10808 ´Â ¿©¼¸°³ ±îÁöÀÇ ³»ºÎ ÆÄ¿ö¼ÇöóÀ̸¦ µ¿½Ã¿¡
°øÀ¯ÇÒ¼öÀÖ´Â ÃæºÐÇÑ ÆÄ¿ö ȯ°æ¼³Á¤À» Áö¿øÇÑ´Ù.
3 + 1 redundancy(Áߺ¹) ȯ°æ¼³Á¤ÀÇ 4°³ÀÇ ÆÄ¿ö ¼ÇöóÀÌ´Â ±â°¡ºñÆ®³ª
10±â±âºñÆ® ÀÌ´õ³Ý Æ÷Æ®·Î fully loaded chassis¸¦ °ÈÇÒ¼öÀÖ´Ù.
3 + 3 ȯ°æ¼³Á¤ÀÇ 6°³ÀÇ ÆÄ¿ö¼ÇöóÀÌ´Â ÀÔ·ÂÆÄ¿ö redundancy(Áߺ¹)
¸¦ Á¦°øÇÒ¼öÀÖ´Ù.
Modular Operating System for Non-Stop Operation
Hitless Software Upgrade
BlackDiamond 10808 Àº hitless ¼ÒÇÁÆ®¿þ¾î ¾÷±×·¹À̵带 Áö¿øÇϸç,
°ü¸®À©µµ¿ì³ª ½ºÀ§Ä¡¸¦ ºÐ¸®ÇÏÁö¾Ê°í ½ºÀ§Ä¡ ¾÷±×·¹À̵带 Çã¿ëÇÑ´Ù.
³×Æ®¿öÅ©
½ÇÁ¦ ÀÛ¾÷½Ã°£À» Áõ°¡½ÃÅ°¸ç BlackDiamond 10808 °¡ ½ºÀ§Ä¡ »ç¿ëÁ¤Áö ¾øÀÌ »õ·Î¿î ¼ÒÇÁÆ®¿þ¾î Ư¡ÀÇ ÀÌÁ¡À» °®µµ·Ï
Çã¿ëÇÑ´Ù.
True Preemptive Multitasking and Protected Memory
ExtremeXOS ´Â OSPF¿Í Figure 3 ¿¡¼ º¸¿©ÁÖµíÀÌ °¢±â ´Ù¸¥°ÍÀ¸·Î
ºÎÅÍ º¸È£µÇ´Â ºÐ¸®µÈ OS¿¡¼ ¿î¿µµÇ´Â ½ºÆд×Æ®¸® °°Àº °¢±â ¸¹Àº
ÀÛ¾÷À»
Çã¿ëÇÑ´Ù.
Process Monitoring and Restart
ExtremeXOS ´Â ½Ç½Ã°£À¸·Î µ¶¸³ÀûÀÎ OS ÇÁ·Î¼¼½º ¿¡¼ ¸ð´ÏÅ͸µ¿¡
ÀÇÇØ ³×Æ®¿öÅ© À̿뼺À» Áõ°¡½ÃŲ´Ù.
¸¸¾à
¾î¶²°ÍÀÌ¶óµµ ÀÀ´äÀÌ ¾ø°Å³ª ÀÛµ¿ÀÌ ÁßÁöµÈ´Ù¸é ÀÚµ¿ÀûÀ¸·Î Àç½ÃÀÛ µÈ´Ù.
Loadable Software Modules
ExtremeXOS ÀÇ ¸ðµâ·¯ ¼³°è´Â »õ·Î¿î OS À̹ÌÁö ¾øÀÌ ±â´ÉÀûÀ¸·Î
½ºÀ§Ä¡ÀÇ È®ÀåÀ» Çã¿ëÇÏ¸ç ½ºÀ§Ä¡¸¦ Àç½ÃÀÛÇÑ´Ù.
High Availability Network Protocols
Ethernet Automatic Protection Switching
EAPS ´Â ź·Â¼º°ú À¯ÀúµéÀÌ ±×µéÀÇ ÀüÅëÀû À½¼º³×Æ®¿öÅ©¿¡ ±â´ëÇÏ´Â
ÀÛ¾÷½Ã°£À» Á¦°øÇϱâÀ§ÇØ IP ³×Æ®¿öÅ© Çã¿ëÇÑ´Ù.
EAPS ´Â Spanning Tree ³ª Rapid Spanning Tree ÇÁ·ÎÅäÄݺ¸´Ù ¿ì¼öÇϸç,
´Ü½Ã°£ ȸº¹À»(50 milliseconds ÀÌÇÏ) Á¦°øÇÏ°í VLAN ¼ö,
³×Æ®¿öÅ© node³ª ÅäÆú·ÎÁö¿¡ °ü°è¾øÀÌ ²ÙÁØÇÑ ´ëüÀÛµ¿À» Àü´ÞÇÑ´Ù.
´ëºÎºÐÀÇ »óȲ¿¡¼, VoIP´Â ¶³¾îÁöÁö ¾ÊÀ¸¸ç EAPS´Â ³×Æ®¿öÅ©°¡ ¸µÅ©
¿À·ù·ÎºÎÅÍ °ÅÀÇ Åõ¸íÇÏ°Ô È¸º¹µÉ¼ö ÀÖµµ·Ï ÇØÁֱ⠶§¹®¿¡
µðÁöÅÐ ºñµð¿À °ø±ÞÀº µ¿°áµÇ°Å³ª pixelizeÈ µÇÁö ¾Ê´Â´Ù.
Spanning Tree/Rapid Spanning Tree Protocols
BlackDiamond 10808 ´Â Layer 2 ź·Â¼ºÀ» À§ÇÏ¿© Spanning Tree,
VLAN Spanning Tree (802.1D), Rapid Spanning Tree (802.1w)
ÇÁ·ÎÅäÄÝÀ»
Áö¿øÇÑ´Ù.
Software Enhanced Availability
Software enhanced availability ´Â ³×Æ®¿öÅ© ÀÎÇÁ¶ó°¡ ºÎºÐÀûÀ¸·Î
ÀÌ»óÀÌ »ý°åÀ»¶§ Á¶Â÷µµ À¯Àú°¡ ³×Æ®¿öÅ©¿¡ Á¢¼ÓÇÑ Ã¤·Î ³²¾ÆÀÖ°Ô
ÇØÁØ´Ù.
BlackDiamond 10808 ½ºÀ§Ä¡´Â OSPF, VRRP ¿Í ESRP (Layer 2 or Layer
3 ¿¡¼ Áö¿øÇÏ´Â) ¿Í°°Àº Áøº¸µÈ Layer 3 ÇÁ·ÎÅäÄÝÀ»
ÀÌ¿ëÇÏ¿© ³×Æ®¿öÅ©
Á¢¼Ó ¿¡¼ÀÇ ¹®Á¦Á¡À» ²ÙÁØÈ÷ üũÇÑ´Ù.
Equal Cost Multipath
Equal Cost Multipath ´Â ¾÷¸µÅ©°¡ ÃæºÐÇÑ ´ëüÀÛµ¿À» Áö¿øÇÏ´Â µ¿¾È¿¡
¼öÇà°ú ºñ¿ëÀý°¨À» À§Çؼ ·Îµå¹ë·¯½º°¡ µÇµµ·ÏÇÑ´Ù.
¸¸¾à ¾÷¸µÅ© ¿À·ù°¡ ¹ß»ýÇÑ´Ù¸é, Æ®·¡ÇÈÀº ÀÚµ¿ÀûÀ¸·Î ³²¾ÆÀÖ´Â ¾÷¸µÅ©·Î
È帣¸ç ¿¬°á»óÅ´ ³²¾ÆÀÖ´Ù.
Link Aggregation (802.3ad)
Cross module link aggregation Àº ´ÜÀÏ Áö¿ª¿¬°á¿¡¼ 8°³±îÁöÀÇ
trunking À» °¡´ÉÇÏ°ÔÇÑ´Ù.
(Áö¿ª¿¬°á¸¶´Ù ÃæºÐÇÑ ´ë¿ªÆøÀÎ 80Gbps ±îÁö)
Scalable Performance
10±â°¡ºñÆ®¿Í ±â°¡ºñÆ® ÀÌ´õ³ÝÆ÷Æ® ¹Ðµµ¸¦ Á¦°øÇÔÀ¸·Î½á,
BlackDiamond 10808 ´Â ±ä±Þ ¿ä±¸»çÇ×°ú IPv4 ¿Í IPv6 ȯ°æÀÎ ±â´ëµÇ´Â
Â÷¼¼´ë ¿ä±¸»çÇ×À» ¸¸Á·½ÃÄÑÁØ´Ù.
System Scalability
Port Density
Æ÷Æ®¹Ðµµ´Â ½ºÀ§Äª ¼Ö·ç¼ÇÀÇ È®À强¿¡ ÇʼöÀûÀÌ´Ù.
´ÜÀÏ
Ãß°¡Æ÷Æ®°¡ ÇÊ¿äÇÑ ¼ø°£¿¡ ´ÜÀϽºÀ§Ä¡¿¡¼ Æ÷Æ® ¿©ºÐÀÌ ¾ø´Ù´Â °¡Á¤¾Æ·¡, ¾îÇø®ÄÉÀ̼ÇÀ»
À§ÇÑ ½ºÀ§Ä¡°¡ Ãß°¡µÈ´Ù¸é °¢±â ½ºÀ§Ä¡ÀÇ
´ë¿ªÆøÀÇ
¹ÝÁ¤µµ±îÁö´Â ¾Æ¸¶µµ ´ÜÁö ½ºÀ§Ä¡ »óÈ£¿¬°á¸¸À» À§ÇÏ¿© Àü¿ëÀ¸·Î ¾²ÀÏ
°ÍÀÌ´Ù.
ÀÌ°á°ú·Î ÀÎÇؼ, ³×Æ®¿öÅ©´Â º¹ÀâÇØÁö¸ç ºñ¿ëÀÌ ¸¹ÀÌ ¼Ò¿äµÈ´Ù.
Ãʱ⿡ ÇÊ¿äÇÑ °Íº¸´Ù ¸¹Àº Æ÷Æ®¸¦ Áö¿øÇϴ°ÍÀ» ´ÜÀÏ ½ºÀ§Ä¡°¡ ¼öÇàÇϵµ·Ï
Ç×»ó ¹Ù¶õ´Ù.
headroom Àº Â÷¼¼´ë ³×Æ®¿öÅ© ¼³°è¸¦ µµ¿ÍÁØ´Ù.(Figure 4 Âü°í)
Application Scalability
QoS Performance
BlackDiamond 10808 ´Â deep packet buffer ¸¦ Àü´ÞÇϸç, ÆøÁÖ»óÅÂ
À϶§ Á¶Â÷µµ ÆÐŶÀº queued(´ë±â) µÉ¼ö ÀÖÀ¸¸ç ½Å·Ú¼ºÀÖ°Ô Àü´ÞµÈ´Ù.
ÀÌ·¯ÇÑ ÆøÁÖ»óÅ µ¿¾È¿¡ ´ë±â»óÅ°¡ Ãß°¡µÉ ¶§¿¡´Â ±âÁ¸ÀÇ Àú±Þ ½ºÀ§Ä¡µéÀº
ÃÊ°úµÇ´Â Æ®·¡ÇÈÀº ¹ö·ÁÁú °ÍÀÌ´Ù.
Æ®·¡ÇÈ ¹öÆÛ¸µÀ¸·Î ÀÎÇØ, ¼¹ö´Â ²÷±è°ú ³×Æ®¿öÅ©¿Í ÄÄÇ»ÅÍ ¿£ÁøÀÇ
±Øµµ·Î Áõ°¡µÇ´Â Æ®·¡ÇÈÀ» ÀçÀü¼ÛÇÒ ÇÊ¿ä°¡ ¾ø´Ù.
Low Latency
ÁýÇÕ ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ³×Æ®¿öÅ· ½ºÀ§Ä¡°¡ ¼±Åõɶ§, ³×Æ®¿öÅ·
ÄÄÆÛ³ÍÆ®¸¦ À§ÇØ ³·Àº ´ë±â½Ã°£ÂÊÀ» ¼±ÅÃÇϴ°ÍÀº ´Ù¸¥¿ä¼Ò¿¡ ÀÇÇØ
µµÀÔµÈ
´ë±â½Ã°£À» À§ÇÑ ¿©ºÐÃß°¡¸¦ Á¦°øÇÑ´Ù.
64-byte ÆÐŶÀ» À§ÇÑ low switching latency 9 microseconds ·Î ÀÎÇؼ,
BlackDiamond 10808 ´Â ÁýÇÕ ¾îÇø®ÄÉÀ̼ǿ¡ ÀÌ»óÀûÀÌ´Ù.
Jumbo Frame Support
9,216 ¹ÙÀÌÆ®¿¡ ´ëÀÀÇÏ´Â Jumbo frames Àº BlackDiamond 10808 ¿¡ÀÇÇØ
Áö¿øµÈ´Ù.
Jumbo frame Àº °í¼öÇà cluster computing ¾îÇø®ÄÉÀ̼ǿ¡ Ưº°È÷
Áß¿äÇϸç, ¿¬±¸µÈ ¹Ù·Î´Â 50% ¸¸ÅÀÇ ¼¹öºÎ´ãÀ» ÁÙ¿©ÁÙ¼öÀÖ´Ù.
Jumbo frame Àº ¶ÇÇÑ ÇÁ·ÎÅäÄÝ overhead(Åë½Å¿¡¼ Á¦¾î ¹× ¿À·ù °Ë»ç¸¦
À§ÇØ Àü¼ÛµÈ Ãß°¡ ÄÚµå)¸¦ ÁÙ¿©ÁÖ¸ç ³ôÀº Àüü ³×Æ®¿öÅ© 󸮷®À»
º¸ÁõÇÑ´Ù.
ÇÁ·ÎÅäÄÝ header°¡ °íÁ¤µÈ Å©±âÀ̱⠶§¹®¿¡, Å«ÇÁ·¹ÀÓÀº ÆÐŶ header¸¦
À§ÇÑ ÆÐŶ payload ÀÇ ³ôÀººñÀ²À» °¡Áø´Ù.
Multicast
BlackDiamond 10808 ´Â Çϵå¿þ¾î ÀÎÁõ°ú ¸ÖƼij½ºÆ® Æ®·¡ÇÈÀÇ replication
À» Áö¿øÇÔ¿¡ ÀÇÇØ, IP ¸ÖƼÄɽºÆ®¿¡¼ Extreme Networks ÀÇ
leadership position À» °¡Á®¿Ô´Ù.
Extreme ³×Æ®¿öÅ©ÀÇ À¯ÀÏÇÑ ½ºÀ§Ä¡ fabric architecture ´Â °°ÀºÆÐŶÀÇ
´Ù¼öÀü¼Û°ú ÀúÀåÀÌ ÇÊ¿äÄ¡¾Ê´Ù.
ÀÌ°ÍÀº ½ºÀ§Ä¡¸¦ ÅëÇÑ ¿î¿µÁßÀÎ ´Ù¸¥ Æ®·¡ÇÈ¿¡ ¿µÇâÀ» ÁÖÁö¾Ê°í ´Ù¼ö
¼öÇàÀ» ¶Ù¾î³ª°Ô ÇÔÀ» È®½ÅÇÑ´Ù.
¸ÖƼij½ºÆ® Ư¡Àº ÀÎÅͳݱ׷ì°ü¸® ÇÁ·ÎÅäÄÝ(IGMPv2 & v3) °ú
ÇÁ·ÎÅäÄÝ µ¶¸³ ¸ÖƼij½ºÆ®(PIM) ¸¦ Æ÷ÇÔÇÑ´Ù.
Sparse Mode ¿Í Dense Mode PIM ¾çÂÊ´Ù Áö¿øµÈ´Ù.
Scalable Management Through Extensibility
Ease of Management
Extreme ³×Æ®¿öÅ©´Â ³×Æ®¿öÅ©¸¦ ´Ù·ç´Âµ¥ ÀÖ¾î¼ ½Ã°£°ú ¸®¼Ò¼Ò¸¦
ÁÙ¿©ÁÖ´Â ¹ßÀüµÈ ÅøÀ» °¡Áö°íÀÖ´Ù.
EPICenter® ´Â ÁýÇÕ³×Æ®¿öÅ©¿¡¼ Extreme ³×Æ®¿öÅ©ÀÇ ´Ù¼ö·¹À̾î
½ºÀ§Äª Àåºñ¸¦ ´Ù·ç±âÀ§ÇÑ ¸ðµç Àå¾Ö ȯ°æ¼³Á¤, Á¤»ê(¾îÄ«¿îÆÃ), ¼öÇà°ú
º¸¾È±â´ÉÀ» Á¦°øÇÑ´Ù.
EPICenter Policy Manager ´Â Layer 1 - 4 ¸¦ À§ÇÑ ·¹ÀÌ¾î µ¶¸³Á¤Ã¥
½ÃÇàÀ» Á¦°øÇÑ´Ù.
Extreme ÀÇ software application, ServiceWatch® ´Â °·ÂÇÑ
Layer 4 - 7 ¸ð´ÏÅ͸µ°ú mission-critical network service ¸¦ À§ÇÑ
°ü¸®¸¦
Àü´ÞÇÑ´Ù.
Extensibility to Integrate New Applications
ExtremeXOS ´Â OS¿Í Á÷°üÀûÀ¸·Î »óÈ£ÀÛ¿ë ÇϱâÀ§ÇØ ³×Æ®¿öÅ©¿¡¼
third-party ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ mechanism À» Á¦°øÇÔÀ¸·Î½á
³×Æ®¿öÅ©
´É·ÂÀÇ À¯¿¬ÇÑ È®ÀåÀ» Çã¿ëÇÑ´Ù. ExtremeXOS ´Â best-of-breed monitoring °ú º¸¾ÈÀåºñ¸¦ ÅëÇÕÇϱâ
À§ÇØ secure
XML-based API¸¦ ÀÌ¿ëÇÑ´Ù.
ÀÌ È®À强Àº »õ·Î¿î ¸ð´ÏÅ͸µ°ú ¹ÝÀÀ´É·ÂÀ» À§ÇÑ closed loop ¸¦
Á¦°øÇϱâÀ§ÇÑ third-party ¾îÇø®ÄÉÀ̼ǰú
ÅëÇÕÀ» Çã¿ëÇÑ´Ù.
Technical Applications
Enterprise Core
BlackDiamond 10808 ´Â ³×Æ®¿öÅ©ÀÇ Çʿ伺À» ¿Ïº®È÷ ¸¸Á·½ÃÅ°´Â ´ë±â¾÷¿¡
ÀÌ»óÀûÀÎ core ½ºÀ§Ä¡ ¼Ö·ç¼ÇÀ» À§ÇÑ ¼ö´ÜÀ» Á¦°øÇÑ´Ù.
BlackDiamond 10808 ÀÇ CLEAR-Flow Security Rules Engine °ú Layer
3 virtual switching ´É·ÂÀº ¹éº» º¸¾ÈÀ» °¡Á®´ÙÁØ´Ù.
Enterprise Data Center
±â¾÷ÀÇ Áß½ÉÀº µ¥ÀÌÅͼ¾ÅÍ¿¡ ÀÖ´Ù.
µ¥ÀÌÅͼ¾ÅÍ´Â
¼ö¸¹Àº ÀüÀÚÀåºñ, ÄÄÇ»ÅÍ ±×¸®°í ³×Æ®¿öÅ© ÀÎÇÁ¶ó¸¦ ¼ö¿ëÇÏ´Â Áß¾ÓÁýÁßÇü º¸¾È ½Ã¼³ÀÌ´Ù.
°ÇÃàÇÐ ÀûÀ¸·Î, Â÷¼¼´ë µ¥ÀÌÅͼ¾ÅÍ´Â ´Ù¾çÇÑ ¾îÇø®ÄÉÀ̼ÇÀ» Áö¿øÇϱâ
À§ÇØ Á¶ÇյɼöÀÖ´Â ¸®¼Ò½ºÀÇ °¡»óÈµÈ °øµ¿½Ã¼³¿¡ ÀÇÁ¸ÇÑ´Ù.
VR ´É·ÂÀÇ BlackDiamond 10808 ´Â Â÷¼¼´ë µ¥ÀÌÅͼ¾ÅÍ ¸®¼Ò½ºÀÇ °¡»óȸ¦
À§ÇÑ ´Ù¸¥Â÷¿øÀ» Á¦°øÇÑ´Ù.
Metro Core Distribution
¸ÞÆ®·Î ÀÌ´õ³Ý ³×Æ®¿öÅ©´Â ÀüÅëÀûÀ¸·Î Customer Edge, Provider Edge
¿Í Provider Aggregation 3°¡Áö ÀåġŸÀÔÀ¸·Î ±¸¼ºµÇ¾îÀÖ´Ù.
*EDGE:[
Enhanced Data GSM Environment ] - 2¼¼´ë À̵¿ Åë½ÅÀÎ GSM Åë½Å¸Á¿¡¼ ÃÖ°í 384kbps ¼ÓµµÀÇ
Á¤º¸¸¦ Àü¼ÛÇÒ ¼ö Àִ ǥÁØ
¸ðµç ³×Æ®¿öÅ©°¡ ÀÌ 3°¡Áö ÀåÄ¡¸¦ ÀÌ¿ëÇÏÁö´Â ¾ÊÀ»°ÍÀÌ´Ù.
¿¹¸¦µé¾î, IPTV ³×Æ®¿öÅ©´Â ´ÜÁö pop(provider point of presence)¿¡¼
provider aggregation ½ºÀ§Ä¡¸¸À» ÀÌ¿ëÇÏ¿© ¹èÄ¡µÉ°ÍÀÌ´Ù.
BlackDiamond 10808 ´Â provider aggregation À̳ª ¸ÞÆ®·Î ÀÌ´õ³Ý
³×Æ®¿öÅ©ÀÇ pop(provider point of presence) ¿¡ ÀûÇÕÇÏ´Ù.
Internet Exchanges
Internet Exchange Point (IXP) ´Â mutual peering agreement ÀÇ
ÀÇ¹Ì·Î½á ±×µéÀÇ ÀÚÄ¡½Ã½ºÅÛ »çÀÌÀÇ ÀÎÅÍ³Ý Æ®·¡ÇÈÀ» ±³È¯ÇϱâÀ§ÇØ
´Ù¸¥ ÀÎÅÍ³Ý ¼ºñ½º °ø±ÞÀÚ(ISP)¸¦ Çã¿ëÇÑ´Ù.
IXP ´Â ±×µéÀÇ °¢±â upstream provider ¿¡¼ Á¾¼Ó¼®À» °¨¼Ò½ÃÅ°±â
À§ÇØ ÀϹÝÀûÀ¸·Î ISP¸¦ ÀÌ¿ëÇÑ´Ù.
µ¡ºÙ¿© ¸»ÇÏÀÚ¸é, È¿À²¼º°ú ¹«Á¤ÁöÇü(fault-tolerance)À» Áõ°¡½ÃÅ°±â
À§ÇÏ¿© »ç¿ëµÇ¾î¿Ô´Ù.
BlackDiamond
10808 ´Â EAPS ¿Í°°Àº ź·Â¼º ±â¼ú°ú Çù·ÂÇÏ¿© »óÈ£¿¬°á ±â¼ú¿¡ µû¶ó¼ ±â°¡ºñÆ®¿Í 10±â°¡ºñÆ® ÀÌ´õ³Ý¿¡ ÀÌ¿ëÇÏ´Â
IXPs ¿¡ ¿ä±¸µÇ´Â
°í¼öÇà°ú ¹«Á¤ÁöÇü Á¢¼Ó¼ºÀÇ Çʿ伺¿¡ ÃÊÁ¡À» ¸ÂÃá´Ù.
High Performance Cluster Computing
High Performance Cluster Computing (HPCC) ´Â °Å´ëÇÑ °è»ê¹®Á¦¸¦
ÇØ°áÇϱâÀ§ÇØ ¼ö¹é°³ ȤÀº ¼öõ°³ÀÇ Çù·ÂÀûÀ¸·Î ¼öÇàÇÏ´Â ¼¹ö·Î
±¸¼ºµÇ¾îÀÖ´Ù.
ºñ±³Àû Àú·ÅÇÏ¸ç ¼ÒÇüÈµÈ 1RU ¼¹öÀÇ ÀÌ¿ëÀ¸·Î, processing power
ÀÇ °Å´ëÇÑ ¾çÀº ºñ¿ëÀý°¨ÀûÀ¸·Î ºñ±³Àû ÀÛÀº°ø°£
À¸·Î µé¾î°¥
¼ö ÀÖ´Ù. BlackDiamond 10808 ´Â »óÈ£¿¬°á ±â¼ú·Î½á ±â°¡ºñÆ®¿Í 10±â°¡ºñÆ®¸¦
ÀÌ¿ëÇÏ´Â HPPC¿¡ ÇÊ¿äÇÑ °í¼öÇà°ú
ºñ¿ëÀý°¨ÀûÀÎ ¿¬°á¼ºÀ» À§ÇÑ Çʿ伺¿¡
ÃÊÁ¡À» ¸ÂÃá´Ù.
TECHNICAL
SPECIFICATIONS
|
|
General
Routing and Switching
|
|
RFC
1812 Requirements for IP Version 4 Routers
|
|
|
RFC
1519 CIDR
|
|
|
RFC
1256 IPv4 ICMP Router Discovery (IRDP)
|
|
|
RFC
1122 Host Requirements
|
|
|
RFC
768 UDP
|
|
|
RFC
791 IP
|
|
|
RFC
792 ICMP
|
|
|
|
|
|
RFC
826 ARP
|
|
|
RFC
894 IP over Ethernet
|
|
|
RFC
1027 Proxy ARP
|
|
|
RFC
1866 HTML - Used for web-based Network Login
|
|
|
RFC
2068 HTTP server - Used for web-based Network Login
|
|
|
RFC
2338 VRRP
|
|
|
RFC
3619 Ethernet Automatic Protection Switching (EAPS)
and EAPSv2
|
|
|
IEEE
802.1D - 1998 Spanning Tree Protocol (STP)
|
|
|
IEEE
802.1w - 2001 Rapid Reconfiguration for STP, RSTP
|
|
|
IEEE
802.1s - 2004 Multiple Instances of STP, MSTP
|
|
|
Extreme
Multiple Instances of Spanning Tree Protocol (EMISTP)
|
|
|
PVST+,
Per VLAN STP (802.1Q interoperable)
|
|
|
Extreme
Standby Router Protocol (ESRP)
|
|
|
IEEE
802.1Q - 1998 Virtual Bridged Local Area Networks
|
|
|
IEEE
802.1AB - LLDP
|
|
|
Extreme
Discovery Protocol (EDP)
|
|
|
Static
Unicast Routes
|
|
|
Extreme
Loop Recovery Protocol (ELRP)
|
|
|
Software
Redundant Ports
|
|
VLANs,
vMANs + MAC-in-MAC
|
|
|
IEEE
802.1Q VLAN Tagging
|
|
|
IEEE
802.3ad Static load sharing configuration and LACP based
dynamic configuration
|
|
|
IEEE
802.1v: VLAN classification by Protocol and Port
|
|
|
Port-based
VLANs
|
|
|
Protocol-based
VLANs
|
|
|
Multiple
STP domains per VLAN
|
|
|
Virtual
MANs (vMANs)
|
|
Quality
of Service and Policies:
|
|
|
IEEE
802.1D -1998 (802.1p) Packet Priority
|
|
|
RFC
2474 DiffServ Precedence, including 8 queues/port
|
|
|
RFC
2598 DiffServ Expedited Forwarding (EF)
|
|
|
RFC
2597 DiffServ Assured Forwarding (AF)
|
|
|
RFC
2475 DiffServ Core and Edge Router Functions
|
|
RIP
|
|
|
RFC
1058 RIP v1
|
|
|
RFC
2453 RIP v2
|
|
OSPF
|
|
|
RFC
2328 OSPF v2 (including MD5 authentication)
|
|
|
RFC
1587 OSPF NSSA Option
|
|
|
RFC
1765 OSPF Database Overflow
|
|
|
RFC
2370 OSPF Opaque LSA Option
|
|
|
RFC
3623 OSPF Graceful Restart
|
|
BGP4
|
|
|
RFC
1771 Border Gateway Protocol 4
|
|
|
RFC
1965 Autonomous System Confederations for BGP
|
|
|
RFC
2796 BGP Route Reflection (supersedes RFC 1966)
|
|
|
RFC
1997 BGP Communities Attribute
|
|
|
RFC
2385 TCP MD5 Authentication for BGPv4
|
|
|
"draft-ietf-idr-restart-10.txt
(Graceful Restart Mechanism for BGP)"
|
|
|
RFC
2439 BGP Route Flap Damping
|
|
|
RFC
2842 Capabilities Advertisement with BGP-4
|
|
|
RFC
2918 Route Refresh Capability for BGP-4
|
|
IPv4
Multicast
|
|
|
RFC
1112 IGMP v1
|
|
|
RFC
2236 IGMP v2
|
|
|
RFC
3376 IGMP v3
|
|
|
IGMP
v1/v2/v3 Snooping with Configurable Router Registration
Forwarding
|
|
|
IGMP
Filters
|
|
|
Static
IGMP Membership
|
|
|
PIM-DM
Draft IETF PIM Dense Mode draft-ietfidmr-pim-dm-05.txt,
draft-ietf-pim-dm-new-v2-04.txt
|
|
|
RFC
3569, draft-ietf-ssm-arch-06.txt PIM-SSM PIM Source
Specific Multicast
|
|
Management
and Traffic Analysis
|
|
|
RFC
2030 SNTP, Simple Network Time Protocol v4
|
|
|
RFC
854 Telnet client and server
|
|
|
RFC
783 TFTP Protocol (revision 2)
|
|
|
RFC
951, 1542 BootP
|
|
|
RFC
2131 BOOTP/DHCP relay agent and DHCP server
|
|
|
RFC
1591 DNS (client operation)
|
|
|
RFC
1155 Structure of Mgmt Information (SMIv1)
|
|
|
RFC
1157 SNMPv1
|
|
|
RFC
1212, RFC 1213, RFC 1215 MIB-II, Ethernet-Like MIB &
TRAPs
|
|
|
RFC
1573 Evolution of Interface
|
|
|
RFC
1650 Ethernet-Like MIB (update of RFC 1213 for SNMPv2)
|
|
|
|
|
RFC
1901 - 1908 SNMP v2c, SMIv2 and Revised MIB-II
|
|
|
RFC
2570 - 2575 SNMPv3, user based security, encryption
and authentication
|
|
|
RFC
2576 Coexistence between SNMP Version 1, Version 2 and
Version 3
|
|
|
RFC
1757 RMON 4 groups: Stats, History, Alarms and Events
|
|
|
RFC
2021 RMON2 (probe configuration)
|
|
|
RFC
2668 802.3 MAU MIB
|
|
|
RFC
1643 Ethernet MIB
|
|
|
RFC
1493 Bridge MIB
|
|
|
RFC
1354 IPv4 Forwarding Table MIB
|
|
|
RFC
2737 Entity MIB v2
|
|
|
RFC
2233 Interface MIB
|
|
|
RFC
1354 IP Forwarding Table MIB
|
|
|
RFC
2737 Entity MIB, Version 2
|
|
|
RFC
2233 Interface MIB
|
|
|
RFC
3621 PoE-MIB (BlackDiamond 8800 only)
|
|
|
RFC
1354 IP Forwarding Table MIB
|
|
|
RFC
1724 RIPv2 MIB
|
|
|
RFC
1850 OSPFv2 MIB
|
|
|
RFC
1657 BGP-4 MIB
|
|
|
Draft-ietf-idr-bgp4-mibv2-02.txt-Enhanced
BGP-4MIB
|
|
|
draft-ietf-pim-mib-v2-o1.txt
|
|
|
RFC
2787 VRRP MIB
|
|
|
RFC
2925 Ping/Traceroute/NSLOOKUP MIB
|
|
|
Draft-ietf-bridge-rstpmib-03.txt
-Definitions of Managed Objects for Bridges with Rapid
Spanning Tree Protocol
|
|
|
Secure
Shell (SSH-2) client and server
|
|
|
Secure
Copy (SCP-2) client and server
|
|
|
Secure
FTP (SFTP) server
|
|
|
sFlow
version 5
|
|
|
Configuration
logging
|
|
|
Multiple
Images, Multiple Configs
|
|
|
BSD
System Logging Protocol (SYSLOG), with Multiple Syslog
Servers
|
|
|
999
Local Messages (criticals stored across reboots)
|
|
|
ExtremeWare
vendor MIBs (includes FDB, PoE, CPU, Memory MIBs) http://www.extremenetworks.
com/services/documentation
|
|
Security
|
|
|
Routing
protocol MD5 authentication (see above)
|
|
|
Secure
Shell (SSH-2), Secure Copy (SCP-2) and SFTP client/server
with encryption/authentication
|
|
|
SNMPv3
user based security, with encryption/authentication
(see above)
|
|
|
RFC
1492 TACACS+
|
|
|
RFC
2138 RADIUS Authentication
|
|
|
RFC
2139 RADIUS Accounting
|
|
|
RADIUS
Per-command Authentication
|
|
|
Access
Profiles on All Routing Protocols
|
|
|
Access
Policies for Telnet/SSH-2/SCP-2
|
|
|
Network
Login - 802.1x, web and MAC-based mechanisms
|
|
|
IEEE
802.1x - 2001 Port-Based Network Access Control for
Network Login
|
|
|
Multiple
supplicants for Network Login (all modes)
|
|
|
Fallback
to local database (MAC and Web-based methods)
|
|
|
Guest
VLAN for 802.1x
|
|
|
SSL/TLS
transport - used for for web-based Network Login, (requires
export controlled encryption module)
|
|
|
MAC
Address Security - Lockdown and Limit
|
|
|
RFC
3046 IP Address Security - DHCP Option 82
|
|
IP
Address Security - Gratuitous ARP Protection
|
|
Layer
2/3/4 ACLs
|
Denial
of Service Protection
|
|
|
RFC
2267 Network Ingress Filtering
|
|
|
RPF
(Unicast Reverse Path Forwarding) Control via ACLs
|
|
|
Wire-speed
ACLs
|
|
|
Rate
Limiting/Shaping by ACLs
|
|
|
IP
Broadcast Forwarding Control
|
|
|
ICMP
and IP-Option Response Control
|
|
|
SYN
attack protection
|
|
|
CPU
DoS Protection with traffic rate limiting to management
CPU
|
|
|
Robust
Against Common Network Attacks
|
|
|
CERT
(http://www.cert.org)
|
|
|
CA-2003-04:
"SQL Slammer"
|
|
|
CA-2002-36:
"SSHredder"
|
|
|
CA-2002-03:
SNMP vulnerabilities
|
|
|
CA-98-13:
tcp-denial-of-service
|
|
|
CA-98.01:
smurf
|
|
|
CA-97.28:
Teardrop_Land -Teardrop and "LAND " attack
|
|
|
CA-96.26:
ping
|
|
|
CA-96.21:
tcp_syn_flooding
|
|
|
CA-96.01:
UDP_service_denial
|
|
|
CA-95.01:
IP_Spoofing_Attacks_and_Hijacked_ Terminal_Connections
|
|
|
IP
Options Attack
|
|
Host
Attacks
|
|
|
Teardrop,
boink, opentear, jolt2, newtear, nestea, syndrop, smurf,
fraggle, papasmurf, synk4, raped, winfreeze, ping -f,
ping of death, pepsi5, Latierra, Winnuke, Simping, Sping,
Ascend, Stream, Land, Octopus
|
|
IPv6
|
|
|
RFC
2460, Internet Protocol, Version 6 (IPv6) Specification
|
|
|
RFC
2461, Neighbor Discovery for IP Version 6, (IPv6)
|
|
|
RFC
2462, IPv6 Stateless Address Auto configuration - Router
Requirements
|
|
|
RFC
2463, Internet Control Message Protocol (ICMPv6) for
the IPv6 Specification
|
|
|
RFC
2466, MIB for ICMPv6
|
|
|
RFC
1981, Path MTU Discovery for IPv6, August 1996 - Router
requirements
|
|
|
RFC
3513, Internet Protocol Version 6 (IPv6) Addressing
Architecture
|
|
|
RFC
3587, Global Unicast Address Format
|
|
|
RFC
2710, IPv6 Multicast Listener Discovery v1 (MLDv1) Protocol
|
|
|
RFC
3810, IPv6 Multicast Listener Discovery v2 (MLDv2) Protocol
|
|
|
RFC
2740, OSPF for IPv6
|
|
|
RFC
2080, RIPng
|
|
|
RFC
2893, Configured Tunnels
|
|
|
RFC
3056, 6to4
|
|
|
Static
Unicast routes for IPv6
|
|
|
Telnet
over IPv6 transport
|
|
|
SSH-2
over IPv6 transport
|
|
|
Ping
over IPv6 transport
|
|
|
Traceroute
over IPv6 transport
|
|
|
|
Switching
Capacity
|
|
|
1.28
Tbps total switching capacity, with 9microsecond latency
for 64-byte packets
|
|
Port
Capacity
|
|
|
48
ports of 10 Gigabit Ethernet
|
|
|
480
1000BASE-X mini-GBIC ports
|
|
|
480
10/100/1000BASE-T ports
|
|
|
Future
support for the emerging 40 and 100 Gigabit Ethernet
standards
|
|
Management
Switch Module
|
|
|
Management
modules contain both the control plane as well as the
switch fabric for the BlackDiamond 10808. Both MSMs
are TCAM-based, and support Longest Prefix Match (LPM)
routing. Two initial versions of MSM are available:
|
|
MSM:1
The MSM-1 includes support for up to 112,000 MAC addresses,
112,000 IP, routes and 64,000 ACLs. MSM-1 is designed
for most mid-sized to large enterprises. MPLS is not
supported on the MSM-1.
|
|
MSM-1XL
The MSM-1XL includes support for up to 224,000 MAC addresses,
224,000 Layer 3 LPM Entries, and 128,000 ACLs. MSM-1XL
is required to run MPLS.
|
|
I/O
Module Options
|
|
G60T
60-port 10/100/1000BASE-T Gigabit Ethernet module (RJ-45)
|
|
G60X
60-port 1000BASE-X Gigabit Ethernet module
|
|
|
Mini-GBIC
modules required. Mini-GBIC options include
|
|
|
-
SX (up to 550m)
|
|
|
-
LX (up to 5km as per standard; up to 10km with 2 Extreme
Networks optics)
|
|
|
-
ZX (up to 70km)
|
|
G20X
20-port 1000BASE-X Gigabit Ethernet module
|
|
|
Mini-GBIC
modules required. Mini-GBIC options include
|
|
|
-
SX (up to 550m)
|
|
|
-
LX (up to 5km as per standard; up to 10km with 2 Extreme
Networks optics)
|
|
|
-
ZX (up to 70km)
|
|
10G6X
6-port 10 Gigabit Ethernet module
|
|
|
XENPAK
modules required XENPAK options include
|
|
|
-
SR (up to 300m)
|
|
|
-
LR (up to 10km)
|
|
|
-
ER (up to 40km)
|
|
|
-
ZR (up to 80km)
|
|
|
-
LX4 (300m MMF, 10km SMF)
|
|
10G2X
2-port 10 Gigabit Ethernet module
|
|
XENPAK
modules required XENPAK options include
|
|
-
SR (up to 300m)
|
|
-
LR (up to 10km)
|
|
-
ER (up to 40km)
|
|
-
ZR (up to 80km)
|
|
-
LX4 (300m MMF, 10km SMF)
|
10G2H
Hybrid module with 2-port 10 Gigabit
|
|
XENPAK
modules required XENPAK options include
|
|
-
SR (up to 300m)
|
|
-
LR (up to 10km)
|
|
-
ER (up to 40km)
|
|
-
ZR (up to 80km)
|
|
-
LX4 (300m MMF, 10km SMF)
|
20-port
1000BASE-X Gigabit Ethernet
|
|
Mini-GBIC
modules required. Mini-GBIC options include:
|
|
-
SR (up to 550m)
|
|
-
LR (up to 5km as per standard; up to 10km with 2 Extreme
Networks optics)
|
20-port
10/100/1000BASE-T Gigabit Ethernet (RJ-45)
|
Power
Supply Options
|
Both
AC and DC power supplies are available.
|
|
AC
power supplies can run from 100Volt to 240Volt, and
deliver
|
|
-
700W at 90V to 100V, or
|
|
-
1200W at 200V to 220V
|
|
48V
DC power supplies deliver 1200W of power
|
|
Dimensions
|
Chassis:
38.5" high (22 RU) x 17.3" wide x 21"
deep (98.0 cm x 44.0 cm x 53.3 cm)
|
MSM
Module Dimensions: 22.7
" high x 17.9" deep x 1.7 width (57.7 cm x
45.5 cm x 4.3 cm)
|
I/O
Module Dimensions:
22.7" high x 19.6" deep x 1.7" width
(57.7 cm x 49.8 cm x 4.3 cm)
|
Weight
|
Empty
Chassis: 105
lb (47.7 kg)
|
Power
Supply: 7 lb
(3.2 kg)
|
MSM-1
Module: 10.5
lb (4.8 kg)
|
MSM-1XL
Module: 10.7
lb (4.9 kg)
|
MSM-1XL
Module: 10.7
lb (4.9 kg)
|
G60T
Module: 8.5
lb (3.9 kg)
|
G60X
Module: 9.25
lb (4.2 kg)
|
G20X
Module: 9.25
lb (4.2 kg)
|
10G6X
Module: 7.75
lb (3.5 kg)
|
10G2X
Module: 7.75
lb (3.5 kg)
|
10G2H
Module: 8.5
lb (3.9 kg)
|
Chassis,
fully loaded (max.): 242
lb (110 kg)
|
Power
|
Chassis
with Fan Trays: 250W,
48V, 5.2A (Heat Dissipation: 853 BTU)
|
MSM-1,
MSM-1XL: 150
W, 48V, 3.125A 335W, 48V, 7.0A (Heat Dissipation: 1144
BTU)
|
G60T:
220W, 48V, 4.6A
(Heat Dissipation: 751 BTU)
|
G60X:
223W, 48V,
4.7A (Heat Dissipation: 761 BTU)
|
G20X:
140W, 48V,
2.9A (Heat Dissipation: 478 BTU)
|
10G6X:
230W, 48V,
4.8A (Heat Dissipation: 785 BTU)
|
10G2X:
145W, 48V,
3.0A (Heat Dissipation: 495 BTU)
|
10G2H:
223W, 48V,
4.7A (Heat Dissipation: 761 BTU) Fully Loaded System
(Chassis + 2 x MSM + 8 x 10G6X): 2760W (Heat Dissipation:
9,421 BTU)
|
|
Operating
Temperature Range:
0° to 40° C
|
Storage
Temperature:
-40° to 70° C
|
Operating
Humidity Range:
10% to 95% relative humidity, non-condensing EN60068
to Extreme IEC68 schedule
|
Regulatory/Safety
|
Safety
Standards
|
|
UL
1950 3rd Edition 2/93, (U.S. Safety of ITE)
|
|
cULus
Listed Equivalent to CAN/CSA-22.2
|
|
No.
950-M93 (Canadian Safety of ITE)
|
|
Low
Voltage Directive (LVD) (European Safety Directive)
|
|
CB
Report and Certificate (International Safety of ITE)
|
|
IEC60950:1991/A1-4
2nd Edition (European Safety of ITE)
|
|
TUV
GS Mark (German Notified Body)
|
|
EN60950:1992/A1-4,A11+
Deviations (European Safety of ITE)
|
|
S/NZS
3260 (Australia Safety Standard)
|
|
S
Mark (Argentina Safety Approval)
|
|
GOST
(Russian Federation Certificate) Laser Devices
|
|
EN60825-1,2:1994,
A11:1996 (European Safety of Lasers Products) FCC 21
CFR Subpart J (U.S. Safety of Laser Products)
|
|
CDRH
Letter of Approval (U.S. FDA Approval)
|
EMI/EMC
Standards
|
|
FCC
47 CFR Part 15 Class A (U.S. Emissions)
|
|
ICES-003
Class A (Canada Emissions)
|
|
89/336/EEC
EMC Directive (European Requirements)
|
|
CISPR22:1997
Class A (International Emissions)
|
|
EN55022:1998
Class A (Europe Emissions)
|
|
EN55024:1998
includes IEC/EN 61000-2,3,4,5,6,11 (Europe Immunity)
|
|
EN
61000-3-2, -3 (Europe Harmonics and Flicker)
|
|
AS/NZS
3548 (Australia Emissions)
|
|
VCCI
Class A (Japan Emissions)
|
|
CNS
13438:1997 Class A (Taiwan Emissions)
|
|
MIC
Mark (Korean Emissions & Immunity Approval)
|
|
NOM/NYCE
(Mexican Product Safety & EMC Authorities)
|
|
Telcordia
GR-1089 (Bellcore Emissions & Immunity Standard)
|
Telecom
Standards
|
|
EN
300 386-2 v1.1.3 (1997-12) (European Telecom Standard)
|
Environmental
|
|
EN60068
to Extreme IEC68 schedule
|
|
ETS
300 019 to Extreme schedule
|
|
Telcordia
GR-63-Core (Bellcore Environmental & Safety Standard)
|
|
|
1-year
on Hardware
|
|
90-days
on Software
|
|
|
Ordering Information
Order Number: |
Description: |
60011 |
BlackDiamond 10808 10-slot Chassis
(Includes Fan Tray) |
60020 |
BlackDiamond
10808/BlackDiamond 8800 700W/1200W 100-240V PSU |
60021 |
BlackDiamond 10808/BlackDiamond 8800 1200W
-48V DC PSU |
60015 |
BlackDiamond 10808
Management and Switch Fabric Module |
60016 |
BlackDiamond 10808 Management and Switch
Fabric Module 1XL |
61010 |
BlackDiamond 10808 60-port
1000BASE-X SFP (mini-GBIC) Module |
61011 |
BlackDiamond 10808 20-port 1000BASE-X SFP
(mini-GBIC) Module |
61030 |
BlackDiamond 10808 60-port
10/100/1000BASE-T RJ-45 Module |
61050 |
BlackDiamond 10808 6-port 10GBASE-X XENPAK
Module |
61051 |
BlackDiamond 10808 2-port
10GBASE-X XENPAK Module |
61071 |
BlackDiamond 10808 hybrid module with -
2-port 10GBASE-X XENPAK - 20-port 1000BASE-X SFP - 20-port
10/100/1000BASE-T RJ-45 |
60012 |
BlackDiamond 10808 Spare
Fan Tray |
60013 |
BlackDiamond 10808 Spare PSU
Controller |
62001 |
BlackDiamond 10808 Blank
Front Panel |
62011 |
BlackDiamond 10808 Mid Mount Kit |
62012 |
BlackDiamond 10808 Spare
Filter 3-pack |
62020 |
BlackDiamond 6808/10808 Cable
Management |
10110 |
10 Gigabit Ethernet XENPAK
Transceiver, 850nm, up to 300m on multimode fiber, SC connector |
10111 |
10 Gigabit Ethernet XENPAK Transceiver,
1310nm, up to 10km on single-mode fiber, SC connector |
10112 |
10 Gigabit Ethernet XENPAK
Transceiver, 1550nm, up to 40km on single-mode fiber, SC connector |
10113 |
10 Gigabit Ethernet XENPAK Transceiver,
1550nm, up to 80km on single-mode fiber, SC connector |
10114 |
10 Gigabit Ethernet WWDM
XENPAK Transceiver, 1310nm up to 300m on multi-mode fiber and up to10km on a
single-mode fiber, SC connector |
10051 |
Mini-GBIC, SFP, 1000Base-SX, LC
connector |
10052 |
Mini-GBIC, SFP,
1000Base-LX, LC connector |
10053 |
Mini-GBIC, SFP, Extra long distance SMF 70
Km/21 dB budget, LC
connector |
|
|