¡æ
Wireless
¡æBlackDiamond
 *Overview
 *BlackDiamond
   12804R

 *BlackDiamond
   12804C

 *BlackDiamond
   10808 Series

 *BlackDiamond
   8800 Series

 *BlackDiamond
   6800 Series

 *Comparison Chart

¡æAlpine
¡æSummit
   

 


BlackDiamond 10808
 Series

 

10±â°¡ºñÆ® ÀÌ´õ³ÝÀ» À§ÇÏ¿© öÀúÇÏ°Ô ¼³°èµÈ, BlackDiamond 10808 ´Â º¸¾È,À̿뼺,¼öÇà¿¡¼­ ÁÖ¿ä±â¼úÀ» ÅëÇÕÇÏ¿´´Ù. Extreme Networks® ´Â Áö´ÉÀûÀÎ core¿Í ¸ðµç ¸ðµâ·¯ ÀÌ´õ³Ý ½ºÀ§Ä¡°¡ ÃøÁ¤µÉ µ¥ÀÌÅͼ¾ÅÍÀÇ Ç¥ÁØÀÌ µÇ¾ú´Ù.

 

BlackDiamond 10808 ´Â Æø³ÐÀº ÇÁ·ÎÅäÄÝÀÇ ¹è¿­À» Áö¿øÇÑ´Ù.

µ¡ºÙ¿©¼­, BlackDiamond 10808´Â ÇÁ·Î±×·¥ÀÌ °¡´ÉÇÑ ASIC technology¸¦ ÅëÇÕÇÏ¿´´Ù.

ÀÌ ÇÁ·Î±×·¥ ´É·ÂÀº Ç÷§ÆûÀÌ ºñ¿ëÀÌ µå´Â Çϵå¿þ¾î ¾÷±×·¹ÀÌµå ¾øÀÌ »õ·Î ÃâÇöÇÏ´Â ÇÁ·ÎÅäÄÝÀ» Áö¿øÇÒ°ÍÀ» È®½ÅÇÑ´Ù.

 

ÀÌµé ¾îÇø®ÄÉÀ̼ÇÀº °í¼öÇà, È®À强, °í¼öÁØÀÇ Åº·Â¼ºÀ» ¿ä±¸ÇÑ´Ù.

´õ¿í Áß¿äÇÑ°ÍÀº, BlackDiamond 10808 ´Â ¿À´Ã³¯ »Ó¸¸¾Æ´Ï¶ó Â÷¼¼´ë¸¦ ÃÊÁ¡À¸·Î ¼³°èµÇ¾ú´Ù.

È®À强Àº Â÷¼¼´ë¿¡ º¯È­ÇÏ´Â ¿ä±¸»çÇ×À» äÅðú ÀÀ´ëÇÒ¼ö ÀÖ´Â Áö´ÉÀûÀÎ core ³×Æ®¿öÅ©¸¦ ±¸ÃàÇϱâÀ§ÇÑ Æ÷ÀÎÆ®´Ù.

ÀÌ°ÍÀº BlackDiamond 10800°¡ ¿Ö ŸÀÇÃßÁ¾À» ºÒÇãÇÏ´ÂÁö ¸»ÇØÁÖ´Â ÀÌÀ¯ÀÌ´Ù.

 

 

Target Applications

BlackDiamond 10808 ´Â ¾îÇø®ÄÉÀ̼ÇÀÇ ´Ù¾çÇÑ ¹è¿­¿¡¼­ ¿ì¼öÇϵµ·Ï ¼³°èµÇ¾ú´Ù. 

  • ÁýÇÕ³×Æ®¿öÅ©¸¦ À§ÇÑ ±â¾÷ ¹éº»½ºÀ§Ä¡
  • mission critical ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ¼­¹ö »óÈ£¿¬°áÀ» Á¦°øÇÏ´Â ±â¾÷µ¥ÀÌÅͼ¾ÅÍ ½ºÀ§Ä¡
  • Triple play ¼­ºñ½º¸¦ Àü´ÞÇÏ´Â ¸ÞÆ®·Î ÄÚ¾î¿Í ¹èÄ¡¸¦ À§ÇÑ ½ºÀ§Ä¡
  • °í´ë¿ªÆø Layer 2 »óÈ£¿¬°áÀ» Á¦°øÇÏ´Â ÀÎÅÍ³Ý ±³·ù¸¦ À§ÇÑ ½ºÀ§Ä¡
  • º¹ÀâÇÑ Computing(°è»ê) ¹®Á¦¸¦ À§ÇÑ ¼Ö·ç¼ÇÀ» Àü´ÞÇÏ´Â °í¼öÇà Ŭ·¯½ºÅÍ ComputingÀ» À§ÇÑ »óÈ£¿¬°á ½ºÀ§Ä¡
     

Security 

  • CLEAR-Flow Security Rules EngineÀÇ Ä§ÀÔŽÁö¿Í ÀÀ´ë
  • Layer 3 virtual switching
  • °­È­µÈ ³×Æ®¿öÅ© ÀÎÇÁ¶ó

 

Voice-Class Availability 

  • Redundant hardware design
  • Modular operating system for non-stop operation with ExtremeXOS¢â Operating System (OS)
  • ÀÌ´õ³Ý ÀÚµ¿¹æ¾î ½ºÀ§Äª(EAPS)À» ÀÌ¿ëÇÏ´Â °íÀ̿뼺 ³×Æ®¿öÅ©

 

Scalable Performance 

  • System scalability with large table sizes, port capacity
  • ¾îÇø®ÄÉÀÌ¼Ç È®À强À» Á¦°øÇÏ´Â Qos¿Í ¸ÖƼij½ºÆ® ¼öÇà
  • È®À强À» ÅëÇÑ ÃøÁ¤°¡´ÉÇÑ °ü¸®

  

Security

BlackDiamond 10808 ´Â ÀÌ´õ³Ý core ³×Æ®¿öÅ·À» À§ÇÑ º¸¾ÈÀÇ »õ·Î¿î ·¹º§À» Àü´ÞÇÑ´Ù.

BlackDiamond 10808 ÇöÀç º¸È£µÇÁö¾Ê´Â ³×Æ®¿öÅ©ÀÇ soft interior ¸¦ º¸È£ÇÔÀ¸·Î½á  perimeter firewallÀ» ÀÌÇàÇÑ´Ù.

»ê¾÷¿¡¼­ °¡Àå ÁøÈ­µÈ CLEAR-Flow Security Rules EngineÀ» ÀÌ¿ëÇÔÀ¸·Î½á, ´Ü½Ã°£¸¸¿¡ ħÀÔÀ§ÇùÀ» ÀÚµ¿ÀûÀ¸·Î ŽÁö¿Í

¿ÏÈ­Çϱâ À§ÇÏ¿© ÇÁ·Î±×·¥ µÉ¼öµµÀÖ´Ù.

  

Threat Detection and Response

CLEAR-Flow Security Rules Engine

CLEAR-Flow Security Rules Engine Àº ³×Æ®¿öÅ©»óÀÇ ¼ö»óÇÑ Æ®·¡ÇÈÀÇ ´õ¸¹Àº ºÐ¼®À» À§ÇØ °¡»óÈ­µÈ º¸¾È ¸®¼Ò½º(VSRs)¸¦ À§ÇÑ

first order ħÀÔŽÁö, °æ°¨ ±×¸®°í mirror Æ®·¡ÇÈÀ» Á¦°øÇÑ´Ù. VSRs ´Â ESF¿¡¼­ ¸¶Áö¸· ºÎºÐÀÌ´Ù.

VSRs ´Â Àüü ´Ù¼ö ±â°¡ºñÆ® ³×Æ®¿öÅ©¸¦ °¡»óÀ¸·Î ÀÌ¿ë°¡´ÉÇÏ´Ù. ±×·¯¹Ç·Î º¸¾È ¼Ö·ç¼ÇÀÇ ºñ¿ëÀý°¨ÀûÀÎ È®À强À» °¡´ÉÇÏ°ÔÇÑ´Ù.

  

Sentriant¢â Àº BlackDiamond 10808 ½ºÀ§Ä¡ÀÇ CLEAR-Flow rule °ú Ãß°¡µÇ´Â Æ®·¡ÇÈ Ãß°¡³ª ½ÃÀÛÁ¡ Ž»ö º¯È­¸¦ À§ÇØ  Á¢±ÙÁ¦¾î ¸ñ·Ï

(ACLs)À» Ãß°¡/¼öÁ¤ÀÌ °¡´ÉÇÏ´Ù. ±×·¯¹Ç·Î ½Ç½Ã°£À¸·Î  fine-grain inspection rules À» À§ÇÑ automated system À» Çã¿ëÇÑ´Ù.

 

Port Mirroring

ħÀÔŽÁö¿Í ¿¹¹æÀ» Áö¿øÇϹǷÎ, BlackDiamond 10808 ´Â many-to-one °ú cross module port mirroringÀ» Áö¿øÇÑ´Ù.

³×Æ®¿öÅ© °ø°Ý¿¡ ´ëÀÀÇÒ¶§ Áø´ÜÅø·Î½á °æÇâºÐ¼®À̳ª ³×Æ®¿öÅ© °ü¸®ÀÚ¿¡ ÀÇÇØ È°¿ëµÇ±â À§ÇÑ Ä§ÀÓŽÁö ÀåÄ¡¿Í °°Àº ¿ÜºÎ ³×Æ®¿öÅ© Àåºñ¸¦

À§ÇÑ Æ®·¡ÇÈ mirror¸¦ À§ÇØ »ç¿ëµÉ¼öÀÖ´Ù.

  

Line-Rate Access Control Lists

ACLs ´Â ³×Æ®¿öÅ© º¸¾È°ú ¹æ¾î ±×¸®°í ³×Æ®¿öÅ© ¸®¼Ò½º È°¿ëÀ» Á¦¾îÇϱâ À§ÇÑ °¡Àå °­·ÂÇÑ ÅøÁõÀÇ ÇϳªÀÌ´Ù.

BlackDiamond 10808 ´Â Layer 2, 3 ±â¹ÝÀÇ 128K ACLs ³ª MAC address ȤÀº IP source/destination address ¿Í °°Àº

4- header information À» Áö¿øÇÑ´Ù.

  

Virtual Router

Layer 3 °¡»ó ½ºÀ§ÄªÀ¸·Î,  BlackDiamond´Â ´Ù¼ö·¹ÀÌ¾î ½ºÀ§ÄªÀ» À§ÇÑ °¡»óÈ­ÀÇ °³³äÀ» °¡Á®´ÙÁØ´Ù.

Layer 3 °¡»ó ½ºÀ§ÄªÀº ´ÜÀϽºÀ§Ä¡¸¦ ´Ù¼öÀÇ °¡»ó ¶ó¿ìÅÍ·Î ºÐÇÒÀ» Çã¿ëÇÑ´Ù.

°¡»ó ¶ó¿ìÅÍ´Â ´ÜÀÏ ¹°¸®Àû ¶ó¿ìÅÍ°¡ ÇØ¿Ô´ø°Í°ú °°Àº ´É·Â°ú ¼Ó¼ºÀ» °¡Áö°íÀÖ´Ù.

ÀÌ°ÍÀº ȯ°æ¼³Á¤, ¿î¿ë ±×¸®°í ¹®Á¦ÇØ°áÀ» À§ÇØ ¸ðµç °°Àº ¶ó¿ìÆà ¸ÞÄ«´ÏÁòÀ» »ó¼ÓÇÑ´Ù.

ÀÌ°ÍÀÇ °á°ú·Î½á, °¢±â °¡»ó ½ºÀ§Ä¡ µµ¸ÞÀÎÀº ºÐ¸®µÇ¾î ´Ù·ç¾îÁö¸ç º¸¾ÈÀ» À§ÇØ °í¸³½ÃÄ×´Ù.

 

 

 ³×Æ®¿öÅ© Æ®·¡ÇÈÀº ¶ÇÇÑ º¸¾ÈÀ§ÇùÀ» ÃÖ¼ÒÈ­Çϱâ À§ÇØ ºÐ¸®µÈ °¡»óµµ¸ÞÀÎÀ¸·Î °í¸³µÉ¼öÀÖ´Ù.

°¡»ó½ºÀ§Ä¡ µµ¸ÞÀÎÀÇ ¼³°è´Â ¶ó¿ìÅÍ Å×À̺íÀÇ ³í¸®Àû ºÐÇÒÀ» °¡´ÉÇÏ°ÔÇÑ´Ù.

Multiple ¶ó¿ìÅÍ Å×À̺íÀº ¶ó¿ìÅÍ °í¸³ÀÌ °¡´ÉÇϸç, ¿î¿µÀÚ°¡ overlapping IP address space ÀÇ ÀÌ¿ëÀ» ÇÒ¼öÀÖ°Ô ÇØÁØ´Ù.

Overlapping IP address spaces ´Â ´ÜÀÏ ¹°¸®Àû ³×Æ®¿öÅ· ÀÎÇÁ¶ó¸¦ °øÀ¯ÇϱâÀ§ÇÑ ´Ù¼ö community¸¦ Çã¿ëÇÑ´Ù.

  

Hardened Network Infrastructure

Denial of Service Protection

BlackDiamond 10808 ´Â Denial of Service (DoS) °ø°ÝÀ» ÈǸ¢ÇÏ°Ô ´Ù·é´Ù.

¸¸¾à cpu ÀÔ·Â ´ë±â¿­¿¡¼­ ºñÁ¤»óÀûÀ¸·Î ¸¹Àº ÆÐŶÀÇ ¼ö¸¦ °¨ÁöÇÑ´Ù¸é, CPU µµ´Þ·ÎºÎÅÍ À̵é ÆÐŶÀ» ÀÚµ¿ÀûÀ¸·Î ¸ØÃß´Â ACLs¸¦

¼ÒÁýÇÒ °ÍÀÌ´Ù. ¾ó¸¶ÈÄ¿¡, ACLs´Â Á¦°ÅµÇ¸ç, °ø°ÝÀÌ °è¼ÓµÈ´Ù¸é, ´Ù½Ã ¼³Ä¡µÈ´Ù.

 

ASIC-based Longest Prefix Match

Longest Prefix Match (LPM) routing Àº »õ·Î¿î È帧À» ¹è¿ì±â À§ÇÑ control plane software ÀÇ Çʿ伺À» °æ°¨½ÃÅ°¸ç DoS °ø°Ý¾Æ·¡ÀÇ

ź·Â¼ºÀ» À§ÇÑ ³×Æ®¿öÅ©¸¦ Çã¿ëÇÑ´Ù. LPMÀ¸·Î ÀÎÇؼ­ CPU´Â ¾î¶°ÇÑ ½ÂÀεÇÁö¾ÊÀº ¸ñÀûÁö¸¦ ÇâÇÑ First PacketÀÇ È帧¿¡ ºÎ´ãÀ»¹ÞÁö

¾ÊÀ¸¸ç, Áß´ëÇÑ ÀÛ¾÷¿¡ ¿µÇâÀ» ¹ÞÁö ¾Ê´Â´Ù.

 

Secure Management

BlackDiamond 10808 ½Ã¸®Áî¿¡ ÀÇÇØ Áö¿øµÇ´Â SSH2, SCP ¿Í SNMPv3 °°Àº ÇÁ·ÎÅäÄÝÀÇ ÀÌ¿ëÀ¸·Î °ü¸®¿î¿ë°ú

man-in-the-middle attackÀÇ ¹æÇظ¦ ¿¹¹æÇÑ´Ù.

 

MD5 Authentication of Routing Protocols

¶ó¿ìÆà ÇÁ·ÎÅäÄÝÀÇ MD5 ½ÂÀÎÀº °ø°ÝÀÚ°¡ À¯È¿¸Þ½ÃÁö º¯°æ°ú ¶ó¿ìÆà ¼¼¼ÇÀ» °ø°ÝÇϴ°ÍÀ» Â÷´ÜÇÑ´Ù.

  

Automated Attack Mitigation

  1. °¨¿°µÈ source ³×Æ®¿öÅ© ÀÔ¼º
  2. BlackDiamond 10808 static ACLs ¿Í CLEAR-Flow rule Àº DoS °ø°ÝÀ» °É·¯³»°í, ¼ö»óÇÑ Æ®·¡ÇÈÀ¸·Î °£ÁÖÇÑ´Ù.
  3. »ó¼¼ÇÑ ºÐ¼®À» À§ÇÑ Sentriant ÇâÇÑ ¼±ÅÃÀûÀÎ port-mirror traffic
  4. Sentriant ´Â ¼ö»óÇÑ Æ®·¡ÇÈ °¨½Ã¸¦ °è¼ÓÀûÀ¸·Î ÇÏ¸ç °æ¹ÌÇÔºÎÅÍ À§Çè´Ü°è±îÁöÀÇ Æ®·¡ÇÈ µî±ÞÀ» È®´ëÇϱâ À§ÇÑ ³»ºÎ±ÔÁ¤À» ÀÌ¿ëÇÑ´Ù.
  5. Sentriant ´Â BlackDiamond 10808 ¿¡ÀÖ´Â ´ÙÀ̳ª¹Í ACLÀ» ½ÃÀÛÇÑ´Ù.
  6. BlackDiamond 10808 ´Â ½Ç½Ã°£À¸·Î dynamic ACL À» Àû¿ëÇÏ¸ç ¼ö»óÇÑ Æ®·¡ÇÈÀÇ port mirror ¸¦ °è¼ÓÇÑ´Ù.
  7. Sentriant also sends the mitigation action to Extreme Networks' EPICenter® network management software.
  8. EPICenter ´Â º¸¾ÈÁ¤Ã¥À» °­È­Çϱâ(mitigation action) À§ÇØ Áß¾Ó°ú ÇϴܽºÀ§Ä¡¿Í Çù·ÂÇÏ¿© ÀÛµ¿ÇÑ´Ù.

 

Voice-Class Availability

°í¼öÇà ³×Æ®¿öÅ© ¿¬°á·Î½á, Á¢¼Ó ·¹À̾¼­ PC¿¬°áÀ̳ª IP telephone ¿¬°á¿¡ »ó°ü¾øÀÌ ÀÌ¿ëµÇ¾î ¿ÔÀ¸¸ç

ȤÀº Ŭ·¯½ºÅÍ¿¡¼­ »óÈ£¿¬°á ¼­¹ö¸¦ À§Çؼ­µµ ÀÌ¿ëµÇ¾ú´Ù.

BlackDiamond 10808 ´Â ½ºÀ§Ä¡ ¼­ºñ½º Áß´Ü ¾øÀÌ ¾÷±×·¹À̵带 À§ÇØ ¸ðµç active component¸¦(OSÆ÷ÇÔ) Çã¿ëÇÑ´Ù.

BlackDiamond 10808 ´Â ¶ÇÇÑ ½ºÀ§Ä¡ÀÇ À̿뼺À» Çâ»ó½ÃÅ°´Â industry leading ExtremeXOS modular operating system À» ÀÌ¿ëÇÑ´Ù.

Network level ź·Â¼º ÇÁ·ÎÅäÄÝÀº ³×Æ®¿öÅ©ÀÇ Åº·Â¼º Çâ»óÀ» À§ÇØ Ãß°¡µÇ¾ú´Ù.

  

Redundant Hardware Design

Redundant Management Modules 

BlackDiamond 10808 ´Â hitless ´ëüÀÛµ¿ ¸ÞÄ«´ÏÁò À¸·Î ±¸¼ºµÇ¾î ÀÖÀ¸¸ç,

°ü¸®½ºÀ§Ä¡ ¸ðµâÀÌ(MSM) ÀÛµ¿ºÒ´ÉÀÌ µÈ´Ù¸é, second MSM ÀÌ Àüü½ºÀ§Ä¡¸¦ À§ÇØ ÀÚµ¿ÀûÀ¸·Î °ü¸®Ã¥ÀÓÀ» Àμö¹ÞÀ»°ÍÀÌ´Ù.

ÀÌƯ¡Àº ¿î¿µÁßÀÎ À½¼º°ú ´Ù¸¥ Áß´ë ¾îÇø®ÄÉÀ̼ǿ¡ ÇʼöÀûÀÌ´Ù.

 

Advanced Chassis Design for Availability

BlackDiamond 10808 ´Â °í¸³Á¦¾î¿Í data plane °°Àº °íÀ̿뼺 ¼³°è ¿ä¼Ò¿¡ ÀÇÇØ º¸ÃæµÇ¾îÁö´Â passive backplane°ú

ÆÄ¿öºÐ¹è¸¦ À§ÇÑ ÃæºÐÇÑ ÄÁÆ®·Ñ·¯ º¸µå¿Í fan control, ³×Æ®¿öÅ©¿¡ ¿µÇâÀ» ÁÖ±âÀü¿¡ ¾Ç¿µÇâÀ» ½Äº°Çϱâ À§ÇÑ È¯°æ ¸ð´ÏÅ͸µÀ» Æ÷ÇÔÇÑ´Ù.

 

Redundant Load Sharing Power Supplies

BlackDiamond 10808 ´Â ¿©¼¸°³ ±îÁöÀÇ ³»ºÎ ÆÄ¿ö¼­ÇöóÀ̸¦ µ¿½Ã¿¡ °øÀ¯ÇÒ¼öÀÖ´Â ÃæºÐÇÑ ÆÄ¿ö ȯ°æ¼³Á¤À» Áö¿øÇÑ´Ù.

3 + 1 redundancy(Áߺ¹) ȯ°æ¼³Á¤ÀÇ 4°³ÀÇ ÆÄ¿ö ¼­ÇöóÀÌ´Â ±â°¡ºñÆ®³ª 10±â±âºñÆ® ÀÌ´õ³Ý Æ÷Æ®·Î fully loaded chassis¸¦ °­È­ÇÒ¼öÀÖ´Ù.

3 + 3 ȯ°æ¼³Á¤ÀÇ 6°³ÀÇ ÆÄ¿ö¼­ÇöóÀÌ´Â ÀÔ·ÂÆÄ¿ö redundancy(Áߺ¹) ¸¦ Á¦°øÇÒ¼öÀÖ´Ù.

  

Modular Operating System for Non-Stop Operation

Hitless Software Upgrade

BlackDiamond 10808 Àº hitless ¼ÒÇÁÆ®¿þ¾î ¾÷±×·¹À̵带 Áö¿øÇϸç, °ü¸®À©µµ¿ì³ª ½ºÀ§Ä¡¸¦ ºÐ¸®ÇÏÁö¾Ê°í ½ºÀ§Ä¡ ¾÷±×·¹À̵带 Çã¿ëÇÑ´Ù.

³×Æ®¿öÅ© ½ÇÁ¦ ÀÛ¾÷½Ã°£À» Áõ°¡½ÃÅ°¸ç BlackDiamond 10808 °¡ ½ºÀ§Ä¡ »ç¿ëÁ¤Áö ¾øÀÌ »õ·Î¿î ¼ÒÇÁÆ®¿þ¾î Ư¡ÀÇ ÀÌÁ¡À» °®µµ·Ï Çã¿ëÇÑ´Ù.

 

True Preemptive Multitasking and Protected Memory

ExtremeXOS ´Â OSPF¿Í Figure 3 ¿¡¼­ º¸¿©ÁÖµíÀÌ °¢±â ´Ù¸¥°ÍÀ¸·Î ºÎÅÍ º¸È£µÇ´Â ºÐ¸®µÈ OS¿¡¼­ ¿î¿µµÇ´Â ½ºÆд×Æ®¸® °°Àº °¢±â ¸¹Àº

ÀÛ¾÷À» Çã¿ëÇÑ´Ù.

 

Process Monitoring and Restart

ExtremeXOS ´Â ½Ç½Ã°£À¸·Î µ¶¸³ÀûÀÎ OS ÇÁ·Î¼¼½º ¿¡¼­ ¸ð´ÏÅ͸µ¿¡ ÀÇÇØ ³×Æ®¿öÅ© À̿뼺À» Áõ°¡½ÃŲ´Ù.

¸¸¾à ¾î¶²°ÍÀÌ¶óµµ ÀÀ´äÀÌ ¾ø°Å³ª ÀÛµ¿ÀÌ ÁßÁöµÈ´Ù¸é ÀÚµ¿ÀûÀ¸·Î Àç½ÃÀÛ µÈ´Ù.

 

Loadable Software Modules

ExtremeXOS ÀÇ ¸ðµâ·¯ ¼³°è´Â »õ·Î¿î OS À̹ÌÁö ¾øÀÌ ±â´ÉÀûÀ¸·Î ½ºÀ§Ä¡ÀÇ È®ÀåÀ» Çã¿ëÇÏ¸ç ½ºÀ§Ä¡¸¦ Àç½ÃÀÛÇÑ´Ù.

  

High Availability Network Protocols

Ethernet Automatic Protection Switching

EAPS ´Â ź·Â¼º°ú À¯ÀúµéÀÌ ±×µéÀÇ ÀüÅëÀû À½¼º³×Æ®¿öÅ©¿¡ ±â´ëÇÏ´Â ÀÛ¾÷½Ã°£À» Á¦°øÇϱâÀ§ÇØ IP ³×Æ®¿öÅ© Çã¿ëÇÑ´Ù.

EAPS ´Â Spanning Tree ³ª Rapid Spanning Tree ÇÁ·ÎÅäÄݺ¸´Ù ¿ì¼öÇϸç, ´Ü½Ã°£ ȸº¹À»(50 milliseconds ÀÌÇÏ) Á¦°øÇÏ°í VLAN ¼ö,

³×Æ®¿öÅ© node³ª ÅäÆú·ÎÁö¿¡ °ü°è¾øÀÌ ²ÙÁØÇÑ ´ëüÀÛµ¿À» Àü´ÞÇÑ´Ù.

´ëºÎºÐÀÇ »óȲ¿¡¼­, VoIP´Â ¶³¾îÁöÁö ¾ÊÀ¸¸ç EAPS´Â ³×Æ®¿öÅ©°¡ ¸µÅ© ¿À·ù·ÎºÎÅÍ °ÅÀÇ Åõ¸íÇÏ°Ô È¸º¹µÉ¼ö ÀÖµµ·Ï ÇØÁֱ⠶§¹®¿¡

µðÁöÅÐ ºñµð¿À °ø±ÞÀº µ¿°áµÇ°Å³ª pixelizeÈ­ µÇÁö ¾Ê´Â´Ù.

 

Spanning Tree/Rapid Spanning Tree Protocols

BlackDiamond 10808 ´Â Layer 2 ź·Â¼ºÀ» À§ÇÏ¿© Spanning Tree, VLAN Spanning Tree (802.1D), Rapid Spanning Tree (802.1w)

ÇÁ·ÎÅäÄÝÀ» Áö¿øÇÑ´Ù.

 

Software Enhanced Availability

Software enhanced availability ´Â ³×Æ®¿öÅ© ÀÎÇÁ¶ó°¡ ºÎºÐÀûÀ¸·Î ÀÌ»óÀÌ »ý°åÀ»¶§ Á¶Â÷µµ À¯Àú°¡ ³×Æ®¿öÅ©¿¡ Á¢¼ÓÇÑ Ã¤·Î ³²¾ÆÀÖ°Ô

ÇØÁØ´Ù. BlackDiamond 10808 ½ºÀ§Ä¡´Â OSPF, VRRP ¿Í ESRP (Layer 2 or Layer 3 ¿¡¼­ Áö¿øÇÏ´Â) ¿Í°°Àº Áøº¸µÈ Layer 3 ÇÁ·ÎÅäÄÝÀ»

ÀÌ¿ëÇÏ¿© ³×Æ®¿öÅ© Á¢¼Ó ¿¡¼­ÀÇ ¹®Á¦Á¡À» ²ÙÁØÈ÷ üũÇÑ´Ù.

 

Equal Cost Multipath

Equal Cost Multipath ´Â ¾÷¸µÅ©°¡ ÃæºÐÇÑ ´ëüÀÛµ¿À» Áö¿øÇÏ´Â µ¿¾È¿¡ ¼öÇà°ú ºñ¿ëÀý°¨À» À§Çؼ­ ·Îµå¹ë·¯½º°¡ µÇµµ·ÏÇÑ´Ù.

¸¸¾à ¾÷¸µÅ© ¿À·ù°¡ ¹ß»ýÇÑ´Ù¸é, Æ®·¡ÇÈÀº ÀÚµ¿ÀûÀ¸·Î ³²¾ÆÀÖ´Â ¾÷¸µÅ©·Î È帣¸ç ¿¬°á»óÅ´ ³²¾ÆÀÖ´Ù.

 

Link Aggregation (802.3ad)

Cross module link aggregation Àº ´ÜÀÏ Áö¿ª¿¬°á¿¡¼­ 8°³±îÁöÀÇ trunking À» °¡´ÉÇÏ°ÔÇÑ´Ù.

(Áö¿ª¿¬°á¸¶´Ù ÃæºÐÇÑ ´ë¿ªÆøÀÎ 80Gbps ±îÁö)

 

 

Scalable Performance

10±â°¡ºñÆ®¿Í ±â°¡ºñÆ® ÀÌ´õ³ÝÆ÷Æ® ¹Ðµµ¸¦ Á¦°øÇÔÀ¸·Î½á,

BlackDiamond 10808 ´Â ±ä±Þ ¿ä±¸»çÇ×°ú IPv4 ¿Í IPv6 ȯ°æÀÎ ±â´ëµÇ´Â Â÷¼¼´ë ¿ä±¸»çÇ×À» ¸¸Á·½ÃÄÑÁØ´Ù.

 

System Scalability

Port Density

Æ÷Æ®¹Ðµµ´Â ½ºÀ§Äª ¼Ö·ç¼ÇÀÇ È®À强¿¡ ÇʼöÀûÀÌ´Ù.

´ÜÀÏ Ãß°¡Æ÷Æ®°¡ ÇÊ¿äÇÑ ¼ø°£¿¡ ´ÜÀϽºÀ§Ä¡¿¡¼­ Æ÷Æ® ¿©ºÐÀÌ ¾ø´Ù´Â °¡Á¤¾Æ·¡, ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ½ºÀ§Ä¡°¡ Ãß°¡µÈ´Ù¸é °¢±â ½ºÀ§Ä¡ÀÇ

´ë¿ªÆøÀÇ ¹ÝÁ¤µµ±îÁö´Â ¾Æ¸¶µµ ´ÜÁö ½ºÀ§Ä¡ »óÈ£¿¬°á¸¸À» À§ÇÏ¿© Àü¿ëÀ¸·Î ¾²ÀÏ °ÍÀÌ´Ù.

ÀÌ°á°ú·Î ÀÎÇؼ­, ³×Æ®¿öÅ©´Â º¹ÀâÇØÁö¸ç ºñ¿ëÀÌ ¸¹ÀÌ ¼Ò¿äµÈ´Ù.

 

Ãʱ⿡ ÇÊ¿äÇÑ °Íº¸´Ù ¸¹Àº Æ÷Æ®¸¦ Áö¿øÇϴ°ÍÀ» ´ÜÀÏ ½ºÀ§Ä¡°¡ ¼öÇàÇϵµ·Ï Ç×»ó ¹Ù¶õ´Ù.

headroom Àº Â÷¼¼´ë ³×Æ®¿öÅ© ¼³°è¸¦ µµ¿ÍÁØ´Ù.(Figure 4 Âü°í)

  

Application Scalability

QoS Performance

BlackDiamond 10808 ´Â deep packet buffer ¸¦ Àü´ÞÇϸç, ÆøÁÖ»óÅ À϶§ Á¶Â÷µµ ÆÐŶÀº queued(´ë±â) µÉ¼ö ÀÖÀ¸¸ç ½Å·Ú¼ºÀÖ°Ô Àü´ÞµÈ´Ù.

ÀÌ·¯ÇÑ ÆøÁÖ»óÅ µ¿¾È¿¡ ´ë±â»óÅ°¡ Ãß°¡µÉ ¶§¿¡´Â ±âÁ¸ÀÇ Àú±Þ ½ºÀ§Ä¡µéÀº ÃÊ°úµÇ´Â Æ®·¡ÇÈÀº ¹ö·ÁÁú °ÍÀÌ´Ù.

Æ®·¡ÇÈ ¹öÆÛ¸µÀ¸·Î ÀÎÇØ, ¼­¹ö´Â ²÷±è°ú ³×Æ®¿öÅ©¿Í ÄÄÇ»ÅÍ ¿£ÁøÀÇ ±Øµµ·Î Áõ°¡µÇ´Â Æ®·¡ÇÈÀ» ÀçÀü¼ÛÇÒ ÇÊ¿ä°¡ ¾ø´Ù.

  

Low Latency

ÁýÇÕ ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ³×Æ®¿öÅ· ½ºÀ§Ä¡°¡ ¼±Åõɶ§, ³×Æ®¿öÅ· ÄÄÆÛ³ÍÆ®¸¦ À§ÇØ ³·Àº ´ë±â½Ã°£ÂÊÀ» ¼±ÅÃÇϴ°ÍÀº ´Ù¸¥¿ä¼Ò¿¡ ÀÇÇØ

µµÀÔµÈ ´ë±â½Ã°£À» À§ÇÑ ¿©ºÐÃß°¡¸¦ Á¦°øÇÑ´Ù.

64-byte ÆÐŶÀ» À§ÇÑ low switching latency 9 microseconds ·Î ÀÎÇؼ­, BlackDiamond 10808 ´Â ÁýÇÕ ¾îÇø®ÄÉÀ̼ǿ¡ ÀÌ»óÀûÀÌ´Ù.

 

Jumbo Frame Support

9,216 ¹ÙÀÌÆ®¿¡ ´ëÀÀÇÏ´Â Jumbo frames Àº BlackDiamond 10808 ¿¡ÀÇÇØ Áö¿øµÈ´Ù.

Jumbo frame Àº °í¼öÇà cluster computing ¾îÇø®ÄÉÀ̼ǿ¡ Ưº°È÷ Áß¿äÇϸç, ¿¬±¸µÈ ¹Ù·Î´Â 50% ¸¸Å­ÀÇ ¼­¹öºÎ´ãÀ» ÁÙ¿©ÁÙ¼öÀÖ´Ù.

Jumbo frame Àº ¶ÇÇÑ ÇÁ·ÎÅäÄÝ overhead(Åë½Å¿¡¼­ Á¦¾î ¹× ¿À·ù °Ë»ç¸¦ À§ÇØ Àü¼ÛµÈ Ãß°¡ ÄÚµå)¸¦ ÁÙ¿©ÁÖ¸ç ³ôÀº Àüü ³×Æ®¿öÅ© 󸮷®À»

º¸ÁõÇÑ´Ù. ÇÁ·ÎÅäÄÝ header°¡ °íÁ¤µÈ Å©±âÀ̱⠶§¹®¿¡, Å«ÇÁ·¹ÀÓÀº ÆÐŶ header¸¦ À§ÇÑ ÆÐŶ payload ÀÇ ³ôÀººñÀ²À» °¡Áø´Ù.

 

Multicast

BlackDiamond 10808 ´Â Çϵå¿þ¾î ÀÎÁõ°ú ¸ÖƼij½ºÆ® Æ®·¡ÇÈÀÇ replication À» Áö¿øÇÔ¿¡ ÀÇÇØ, IP ¸ÖƼÄɽºÆ®¿¡¼­ Extreme Networks ÀÇ

leadership position À» °¡Á®¿Ô´Ù.

Extreme ³×Æ®¿öÅ©ÀÇ À¯ÀÏÇÑ ½ºÀ§Ä¡ fabric architecture ´Â °°ÀºÆÐŶÀÇ ´Ù¼öÀü¼Û°ú ÀúÀåÀÌ ÇÊ¿äÄ¡¾Ê´Ù.

ÀÌ°ÍÀº ½ºÀ§Ä¡¸¦ ÅëÇÑ ¿î¿µÁßÀÎ ´Ù¸¥ Æ®·¡ÇÈ¿¡ ¿µÇâÀ» ÁÖÁö¾Ê°í ´Ù¼ö ¼öÇàÀ» ¶Ù¾î³ª°Ô ÇÔÀ» È®½ÅÇÑ´Ù.

¸ÖƼij½ºÆ® Ư¡Àº ÀÎÅͳݱ׷ì°ü¸® ÇÁ·ÎÅäÄÝ(IGMPv2 & v3) °ú ÇÁ·ÎÅäÄÝ µ¶¸³ ¸ÖƼij½ºÆ®(PIM) ¸¦ Æ÷ÇÔÇÑ´Ù.

Sparse Mode ¿Í Dense Mode PIM ¾çÂÊ´Ù Áö¿øµÈ´Ù.

  

Scalable Management Through Extensibility

Ease of Management

Extreme ³×Æ®¿öÅ©´Â ³×Æ®¿öÅ©¸¦ ´Ù·ç´Âµ¥ À־ ½Ã°£°ú ¸®¼Ò¼Ò¸¦ ÁÙ¿©ÁÖ´Â ¹ßÀüµÈ ÅøÀ» °¡Áö°íÀÖ´Ù.

EPICenter® ´Â ÁýÇÕ³×Æ®¿öÅ©¿¡¼­ Extreme ³×Æ®¿öÅ©ÀÇ ´Ù¼ö·¹ÀÌ¾î ½ºÀ§Äª Àåºñ¸¦ ´Ù·ç±âÀ§ÇÑ ¸ðµç Àå¾Ö ȯ°æ¼³Á¤, Á¤»ê(¾îÄ«¿îÆÃ), ¼öÇà°ú

º¸¾È±â´ÉÀ» Á¦°øÇÑ´Ù. EPICenter Policy Manager ´Â Layer 1 - 4 ¸¦ À§ÇÑ ·¹ÀÌ¾î µ¶¸³Á¤Ã¥ ½ÃÇàÀ» Á¦°øÇÑ´Ù.

Extreme ÀÇ software application, ServiceWatch® ´Â °­·ÂÇÑ Layer 4 - 7 ¸ð´ÏÅ͸µ°ú mission-critical network service ¸¦ À§ÇÑ °ü¸®¸¦

Àü´ÞÇÑ´Ù.

 

Extensibility to Integrate New Applications

ExtremeXOS ´Â OS¿Í Á÷°üÀûÀ¸·Î »óÈ£ÀÛ¿ë ÇϱâÀ§ÇØ ³×Æ®¿öÅ©¿¡¼­ third-party ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ mechanism À» Á¦°øÇÔÀ¸·Î½á

³×Æ®¿öÅ© ´É·ÂÀÇ À¯¿¬ÇÑ È®ÀåÀ» Çã¿ëÇÑ´Ù. ExtremeXOS ´Â best-of-breed monitoring °ú º¸¾ÈÀåºñ¸¦ ÅëÇÕÇϱâ À§ÇØ secure

XML-based API¸¦ ÀÌ¿ëÇÑ´Ù. ÀÌ È®À强Àº »õ·Î¿î ¸ð´ÏÅ͸µ°ú ¹ÝÀÀ´É·ÂÀ» À§ÇÑ closed loop ¸¦ Á¦°øÇϱâÀ§ÇÑ third-party ¾îÇø®ÄÉÀ̼ǰú

ÅëÇÕÀ» Çã¿ëÇÑ´Ù.

 

 

Technical Applications 

Enterprise Core

BlackDiamond 10808 ´Â ³×Æ®¿öÅ©ÀÇ Çʿ伺À» ¿Ïº®È÷ ¸¸Á·½ÃÅ°´Â ´ë±â¾÷¿¡ ÀÌ»óÀûÀÎ core ½ºÀ§Ä¡ ¼Ö·ç¼ÇÀ» À§ÇÑ ¼ö´ÜÀ» Á¦°øÇÑ´Ù.

BlackDiamond 10808 ÀÇ CLEAR-Flow Security Rules Engine °ú Layer 3 virtual switching ´É·ÂÀº ¹éº» º¸¾ÈÀ» °¡Á®´ÙÁØ´Ù.

  

Enterprise Data Center

±â¾÷ÀÇ Áß½ÉÀº µ¥ÀÌÅͼ¾ÅÍ¿¡ ÀÖ´Ù.

µ¥ÀÌÅͼ¾ÅÍ´Â ¼ö¸¹Àº ÀüÀÚÀåºñ, ÄÄÇ»ÅÍ ±×¸®°í ³×Æ®¿öÅ© ÀÎÇÁ¶ó¸¦ ¼ö¿ëÇÏ´Â Áß¾ÓÁýÁßÇü º¸¾È ½Ã¼³ÀÌ´Ù.

°ÇÃàÇÐ ÀûÀ¸·Î, Â÷¼¼´ë µ¥ÀÌÅͼ¾ÅÍ´Â ´Ù¾çÇÑ ¾îÇø®ÄÉÀ̼ÇÀ» Áö¿øÇϱâ À§ÇØ Á¶ÇյɼöÀÖ´Â ¸®¼Ò½ºÀÇ °¡»óÈ­µÈ °øµ¿½Ã¼³¿¡ ÀÇÁ¸ÇÑ´Ù.

VR ´É·ÂÀÇ BlackDiamond 10808 ´Â Â÷¼¼´ë µ¥ÀÌÅͼ¾ÅÍ ¸®¼Ò½ºÀÇ °¡»óÈ­¸¦ À§ÇÑ ´Ù¸¥Â÷¿øÀ» Á¦°øÇÑ´Ù.

  

Metro Core Distribution    

¸ÞÆ®·Î ÀÌ´õ³Ý ³×Æ®¿öÅ©´Â ÀüÅëÀûÀ¸·Î Customer Edge, Provider Edge ¿Í Provider Aggregation 3°¡Áö ÀåġŸÀÔÀ¸·Î ±¸¼ºµÇ¾îÀÖ´Ù.

*EDGE:[ Enhanced Data GSM Environment ] - 2¼¼´ë À̵¿ Åë½ÅÀÎ GSM Åë½Å¸Á¿¡¼­ ÃÖ°í 384kbps ¼ÓµµÀÇ Á¤º¸¸¦ Àü¼ÛÇÒ ¼ö Àִ ǥÁØ

¸ðµç ³×Æ®¿öÅ©°¡ ÀÌ 3°¡Áö ÀåÄ¡¸¦ ÀÌ¿ëÇÏÁö´Â ¾ÊÀ»°ÍÀÌ´Ù.  

¿¹¸¦µé¾î, IPTV ³×Æ®¿öÅ©´Â ´ÜÁö pop(provider point of presence)¿¡¼­ provider aggregation ½ºÀ§Ä¡¸¸À» ÀÌ¿ëÇÏ¿© ¹èÄ¡µÉ°ÍÀÌ´Ù.

BlackDiamond 10808 ´Â provider aggregation À̳ª ¸ÞÆ®·Î ÀÌ´õ³Ý ³×Æ®¿öÅ©ÀÇ pop(provider point of presence) ¿¡ ÀûÇÕÇÏ´Ù.

  

Internet Exchanges

Internet Exchange Point (IXP) ´Â mutual peering agreement ÀÇ ÀÇ¹Ì·Î½á ±×µéÀÇ ÀÚÄ¡½Ã½ºÅÛ »çÀÌÀÇ ÀÎÅÍ³Ý Æ®·¡ÇÈÀ» ±³È¯ÇϱâÀ§ÇØ

´Ù¸¥ ÀÎÅÍ³Ý ¼­ºñ½º °ø±ÞÀÚ(ISP)¸¦ Çã¿ëÇÑ´Ù.

IXP ´Â ±×µéÀÇ °¢±â upstream provider ¿¡¼­ Á¾¼Ó¼®À» °¨¼Ò½ÃÅ°±â À§ÇØ ÀϹÝÀûÀ¸·Î ISP¸¦ ÀÌ¿ëÇÑ´Ù.

µ¡ºÙ¿© ¸»ÇÏÀÚ¸é, È¿À²¼º°ú ¹«Á¤ÁöÇü(fault-tolerance)À» Áõ°¡½ÃÅ°±â À§ÇÏ¿© »ç¿ëµÇ¾î¿Ô´Ù.

BlackDiamond 10808 ´Â EAPS ¿Í°°Àº ź·Â¼º ±â¼ú°ú Çù·ÂÇÏ¿© »óÈ£¿¬°á ±â¼ú¿¡ µû¶ó¼­ ±â°¡ºñÆ®¿Í 10±â°¡ºñÆ® ÀÌ´õ³Ý¿¡ ÀÌ¿ëÇÏ´Â

IXPs ¿¡ ¿ä±¸µÇ´Â °í¼öÇà°ú ¹«Á¤ÁöÇü Á¢¼Ó¼ºÀÇ Çʿ伺¿¡ ÃÊÁ¡À» ¸ÂÃá´Ù.

 

 

High Performance Cluster Computing

High Performance Cluster Computing (HPCC) ´Â °Å´ëÇÑ °è»ê¹®Á¦¸¦ ÇØ°áÇϱâÀ§ÇØ ¼ö¹é°³ ȤÀº ¼öõ°³ÀÇ Çù·ÂÀûÀ¸·Î ¼öÇàÇÏ´Â ¼­¹ö·Î

±¸¼ºµÇ¾îÀÖ´Ù. ºñ±³Àû Àú·ÅÇÏ¸ç ¼ÒÇüÈ­µÈ 1RU ¼­¹öÀÇ ÀÌ¿ëÀ¸·Î, processing power ÀÇ °Å´ëÇÑ ¾çÀº ºñ¿ëÀý°¨ÀûÀ¸·Î ºñ±³Àû ÀÛÀº°ø°£

À¸·Î µé¾î°¥ ¼ö ÀÖ´Ù. BlackDiamond 10808 ´Â »óÈ£¿¬°á ±â¼ú·Î½á ±â°¡ºñÆ®¿Í 10±â°¡ºñÆ®¸¦ ÀÌ¿ëÇÏ´Â HPPC¿¡ ÇÊ¿äÇÑ °í¼öÇà°ú

ºñ¿ëÀý°¨ÀûÀÎ ¿¬°á¼ºÀ» À§ÇÑ Çʿ伺¿¡ ÃÊÁ¡À» ¸ÂÃá´Ù.

 

 

 

 

TECHNICAL SPECIFICATIONS

ExtremeXOS V11.4 Supported Protocols

General Routing and Switching

 

RFC 1812 Requirements for IP Version 4 Routers

 

RFC 1519 CIDR

 

 

RFC 1256 IPv4 ICMP Router Discovery (IRDP)

 

 

RFC 1122 Host Requirements

 

RFC 768 UDP

 

RFC 791 IP

 

RFC 792 ICMP

 

 

RFC 793 TCP

 

 

RFC 826 ARP

 

RFC 894 IP over Ethernet

 

 

RFC 1027 Proxy ARP

 

 

RFC 1866 HTML - Used for web-based Network Login

 

 

RFC 2068 HTTP server - Used for web-based Network Login

 

RFC 2338 VRRP

 

RFC 3619 Ethernet Automatic Protection Switching (EAPS) and EAPSv2

 

IEEE 802.1D - 1998 Spanning Tree Protocol (STP)

 

IEEE 802.1w - 2001 Rapid Reconfiguration for STP, RSTP

 

IEEE 802.1s - 2004 Multiple Instances of STP, MSTP

 

Extreme Multiple Instances of Spanning Tree Protocol (EMISTP)

 

PVST+, Per VLAN STP (802.1Q interoperable)

 

Extreme Standby Router Protocol (ESRP)

 

 

IEEE 802.1Q - 1998 Virtual Bridged Local Area Networks

 

 

IEEE 802.1AB - LLDP

 

 

Extreme Discovery Protocol (EDP)

 

 

Static Unicast Routes

 

 

Extreme Loop Recovery Protocol (ELRP)

 

Software Redundant Ports

 

VLANs, vMANs + MAC-in-MAC

 

IEEE 802.1Q VLAN Tagging

 

IEEE 802.3ad Static load sharing configuration and LACP based dynamic configuration

 

IEEE 802.1v: VLAN classification by Protocol and Port

 

Port-based VLANs

 

 

Protocol-based VLANs

 

Multiple STP domains per VLAN

 

Virtual MANs (vMANs)

 

Quality of Service and Policies:

 

IEEE 802.1D -1998 (802.1p) Packet Priority

 

RFC 2474 DiffServ Precedence, including 8 queues/port

 

RFC 2598 DiffServ Expedited Forwarding (EF)

 

RFC 2597 DiffServ Assured Forwarding (AF)

 

 

RFC 2475 DiffServ Core and Edge Router Functions

 

RIP

 

 

RFC 1058 RIP v1

 

 

RFC 2453 RIP v2

 

OSPF

 

 

RFC 2328 OSPF v2 (including MD5 authentication)

 

RFC 1587 OSPF NSSA Option

 

 

RFC 1765 OSPF Database Overflow

 

 

RFC 2370 OSPF Opaque LSA Option

 

 

RFC 3623 OSPF Graceful Restart

 

BGP4

 

 

RFC 1771 Border Gateway Protocol 4

 

 

RFC 1965 Autonomous System Confederations for BGP

 

 

RFC 2796 BGP Route Reflection (supersedes RFC 1966)

 

 

RFC 1997 BGP Communities Attribute

 

RFC 2385 TCP MD5 Authentication for BGPv4

 

"draft-ietf-idr-restart-10.txt (Graceful Restart Mechanism for BGP)"

 

RFC 2439 BGP Route Flap Damping

 

RFC 2842 Capabilities Advertisement with BGP-4

 

RFC 2918 Route Refresh Capability for BGP-4

 

IPv4 Multicast

 

RFC 1112 IGMP v1

 

RFC 2236 IGMP v2

 

RFC 3376 IGMP v3

 

IGMP v1/v2/v3 Snooping with Configurable Router Registration Forwarding

 

IGMP Filters

 

Static IGMP Membership

 

PIM-DM Draft IETF PIM Dense Mode draft-ietfidmr-pim-dm-05.txt, draft-ietf-pim-dm-new-v2-04.txt

 

RFC 3569, draft-ietf-ssm-arch-06.txt PIM-SSM PIM Source Specific Multicast

 

Management and Traffic Analysis

 

RFC 2030 SNTP, Simple Network Time Protocol v4

 

RFC 854 Telnet client and server

 

RFC 783 TFTP Protocol (revision 2)

 

RFC 951, 1542 BootP

 

RFC 2131 BOOTP/DHCP relay agent and DHCP server

 

RFC 1591 DNS (client operation)

 

RFC 1155 Structure of Mgmt Information (SMIv1)

 

RFC 1157 SNMPv1

 

RFC 1212, RFC 1213, RFC 1215 MIB-II, Ethernet-Like MIB & TRAPs

 

RFC 1573 Evolution of Interface

 

RFC 1650 Ethernet-Like MIB (update of RFC 1213 for SNMPv2)

 

 

 

RFC 1901 - 1908 SNMP v2c, SMIv2 and Revised MIB-II

 

RFC 2570 - 2575 SNMPv3, user based security, encryption and authentication

 

RFC 2576 Coexistence between SNMP Version 1, Version 2 and Version 3

 

RFC 1757 RMON 4 groups: Stats, History, Alarms and Events

 

RFC 2021 RMON2 (probe configuration)

 

RFC 2668 802.3 MAU MIB

 

RFC 1643 Ethernet MIB

 

RFC 1493 Bridge MIB

 

RFC 1354 IPv4 Forwarding Table MIB

 

RFC 2737 Entity MIB v2

 

RFC 2233 Interface MIB

 

RFC 1354 IP Forwarding Table MIB

 

RFC 2737 Entity MIB, Version 2

 

RFC 2233 Interface MIB

 

RFC 3621 PoE-MIB (BlackDiamond 8800 only)

 

RFC 1354 IP Forwarding Table MIB

 

RFC 1724 RIPv2 MIB

 

RFC 1850 OSPFv2 MIB

 

RFC 1657 BGP-4 MIB

 

Draft-ietf-idr-bgp4-mibv2-02.txt-Enhanced BGP-4MIB

 

draft-ietf-pim-mib-v2-o1.txt

 

RFC 2787 VRRP MIB

 

RFC 2925 Ping/Traceroute/NSLOOKUP MIB

 

Draft-ietf-bridge-rstpmib-03.txt -Definitions of Managed Objects for Bridges with Rapid Spanning Tree Protocol

 

Secure Shell (SSH-2) client and server

 

Secure Copy (SCP-2) client and server

 

Secure FTP (SFTP) server

 

sFlow version 5

 

Configuration logging

 

Multiple Images, Multiple Configs

 

BSD System Logging Protocol (SYSLOG), with Multiple Syslog Servers

 

999 Local Messages (criticals stored across reboots)

 

ExtremeWare vendor MIBs (includes FDB, PoE, CPU, Memory MIBs) http://www.extremenetworks. com/services/documentation

 

Security

 

 

Routing protocol MD5 authentication (see above)

 

 

Secure Shell (SSH-2), Secure Copy (SCP-2) and SFTP client/server with encryption/authentication

 

 

SNMPv3 user based security, with encryption/authentication (see above)

 

RFC 1492 TACACS+

 

RFC 2138 RADIUS Authentication

 

RFC 2139 RADIUS Accounting

 

 

RADIUS Per-command Authentication

 

Access Profiles on All Routing Protocols

 

 

Access Policies for Telnet/SSH-2/SCP-2

 

 

Network Login - 802.1x, web and MAC-based mechanisms

 

 

IEEE 802.1x - 2001 Port-Based Network Access Control for Network Login

 

Multiple supplicants for Network Login (all modes)

 

 

Fallback to local database (MAC and Web-based methods)

 

 

Guest VLAN for 802.1x

 

 

SSL/TLS transport - used for for web-based Network Login, (requires export controlled encryption module)

 

 

MAC Address Security - Lockdown and Limit

 

RFC 3046 IP Address Security - DHCP Option 82

IP Address Security - Gratuitous ARP Protection

Layer 2/3/4 ACLs

Denial of Service Protection

 

 

RFC 2267 Network Ingress Filtering

 

 

RPF (Unicast Reverse Path Forwarding) Control via ACLs

 

 

Wire-speed ACLs

 

 

Rate Limiting/Shaping by ACLs

 

 

IP Broadcast Forwarding Control

 

 

ICMP and IP-Option Response Control

 

 

SYN attack protection

 

CPU DoS Protection with traffic rate limiting to management CPU

 

Robust Against Common Network Attacks

 

 

CERT (http://www.cert.org)

 

 

CA-2003-04: "SQL Slammer"

 

 

CA-2002-36: "SSHredder"

 

 

CA-2002-03: SNMP vulnerabilities

 

 

CA-98-13: tcp-denial-of-service

 

 

CA-98.01: smurf

 

 

CA-97.28: Teardrop_Land -Teardrop and "LAND " attack

 

 

CA-96.26: ping

 

 

CA-96.21: tcp_syn_flooding

 

 

CA-96.01: UDP_service_denial

 

 

CA-95.01: IP_Spoofing_Attacks_and_Hijacked_ Terminal_Connections

 

IP Options Attack

 

Host Attacks

 

 

Teardrop, boink, opentear, jolt2, newtear, nestea, syndrop, smurf, fraggle, papasmurf, synk4, raped, winfreeze, ping -f, ping of death, pepsi5, Latierra, Winnuke, Simping, Sping, Ascend, Stream, Land, Octopus

 

IPv6

 

 

RFC 2460, Internet Protocol, Version 6 (IPv6) Specification

 

 

RFC 2461, Neighbor Discovery for IP Version 6, (IPv6)

 

 

RFC 2462, IPv6 Stateless Address Auto configuration - Router Requirements

 

 

RFC 2463, Internet Control Message Protocol (ICMPv6) for the IPv6 Specification

 

 

RFC 2466, MIB for ICMPv6

 

 

RFC 1981, Path MTU Discovery for IPv6, August 1996 - Router requirements

 

RFC 3513, Internet Protocol Version 6 (IPv6) Addressing Architecture

 

 

RFC 3587, Global Unicast Address Format

 

RFC 2710, IPv6 Multicast Listener Discovery v1 (MLDv1) Protocol

 

 

RFC 3810, IPv6 Multicast Listener Discovery v2 (MLDv2) Protocol

 

 

RFC 2740, OSPF for IPv6

 

RFC 2080, RIPng

 

RFC 2893, Configured Tunnels

 

RFC 3056, 6to4

 

Static Unicast routes for IPv6

 

Telnet over IPv6 transport

 

SSH-2 over IPv6 transport

 

Ping over IPv6 transport

 

Traceroute over IPv6 transport

 

General Specifications

 

Switching Capacity

 

1.28 Tbps total switching capacity, with 9microsecond latency for 64-byte packets

 

Port Capacity

 

48 ports of 10 Gigabit Ethernet

 

480 1000BASE-X mini-GBIC ports

 

480 10/100/1000BASE-T ports

 

Future support for the emerging 40 and 100 Gigabit Ethernet standards

 

Management Switch Module

 

Management modules contain both the control plane as well as the switch fabric for the BlackDiamond 10808. Both MSMs are TCAM-based, and support Longest Prefix Match (LPM) routing. Two initial versions of MSM are available:

 

MSM:1 The MSM-1 includes support for up to 112,000 MAC addresses, 112,000 IP, routes and 64,000 ACLs. MSM-1 is designed for most mid-sized to large enterprises. MPLS is not supported on the MSM-1.

 

MSM-1XL The MSM-1XL includes support for up to 224,000 MAC addresses, 224,000 Layer 3 LPM Entries, and 128,000 ACLs. MSM-1XL is required to run MPLS.

 

I/O Module Options

 

G60T 60-port 10/100/1000BASE-T Gigabit Ethernet module (RJ-45)

 

G60X 60-port 1000BASE-X Gigabit Ethernet module

 

Mini-GBIC modules required. Mini-GBIC options include

 

 

- SX (up to 550m)

 

 

- LX (up to 5km as per standard; up to 10km with 2 Extreme Networks optics)

 

 

- ZX (up to 70km)

 

G20X 20-port 1000BASE-X Gigabit Ethernet module

 

Mini-GBIC modules required. Mini-GBIC options include

 

 

- SX (up to 550m)

 

 

- LX (up to 5km as per standard; up to 10km with 2 Extreme Networks optics)

 

 

- ZX (up to 70km)

 

10G6X 6-port 10 Gigabit Ethernet module

 

XENPAK modules required XENPAK options include

 

 

- SR (up to 300m)

 

 

- LR (up to 10km)

 

 

- ER (up to 40km)

 

 

- ZR (up to 80km)

 

 

- LX4 (300m MMF, 10km SMF)

 

10G2X 2-port 10 Gigabit Ethernet module

XENPAK modules required XENPAK options include

 

- SR (up to 300m)

 

- LR (up to 10km)

 

- ER (up to 40km)

 

- ZR (up to 80km)

 

- LX4 (300m MMF, 10km SMF)

10G2H Hybrid module with 2-port 10 Gigabit

XENPAK modules required XENPAK options include

 

- SR (up to 300m)

 

- LR (up to 10km)

 

- ER (up to 40km)

 

- ZR (up to 80km)

 

- LX4 (300m MMF, 10km SMF)

20-port 1000BASE-X Gigabit Ethernet

Mini-GBIC modules required. Mini-GBIC options include:

 

- SR (up to 550m)

 

- LR (up to 5km as per standard; up to 10km with 2 Extreme Networks optics)

20-port 10/100/1000BASE-T Gigabit Ethernet (RJ-45)

Power Supply Options

Both AC and DC power supplies are available.

AC power supplies can run from 100Volt to 240Volt, and deliver

 

- 700W at 90V to 100V, or

 

- 1200W at 200V to 220V

48V DC power supplies deliver 1200W of power

Physical Specifications

Dimensions

Chassis: 38.5" high (22 RU) x 17.3" wide x 21" deep (98.0 cm x 44.0 cm x 53.3 cm)

MSM Module Dimensions: 22.7 " high x 17.9" deep x 1.7 width (57.7 cm x 45.5 cm x 4.3 cm)

I/O Module Dimensions: 22.7" high x 19.6" deep x 1.7" width (57.7 cm x 49.8 cm x 4.3 cm)

Weight

Empty Chassis: 105 lb (47.7 kg)

Power Supply: 7 lb (3.2 kg)

MSM-1 Module: 10.5 lb (4.8 kg)

MSM-1XL Module: 10.7 lb (4.9 kg)

MSM-1XL Module: 10.7 lb (4.9 kg)

G60T Module: 8.5 lb (3.9 kg)

G60X Module: 9.25 lb (4.2 kg)

G20X Module: 9.25 lb (4.2 kg)

10G6X Module: 7.75 lb (3.5 kg)

10G2X Module: 7.75 lb (3.5 kg)

10G2H Module: 8.5 lb (3.9 kg)

Chassis, fully loaded (max.): 242 lb (110 kg)

Power

Chassis with Fan Trays: 250W, 48V, 5.2A (Heat Dissipation: 853 BTU)

MSM-1, MSM-1XL: 150 W, 48V, 3.125A 335W, 48V, 7.0A (Heat Dissipation: 1144 BTU)

G60T: 220W, 48V, 4.6A (Heat Dissipation: 751 BTU)

G60X: 223W, 48V, 4.7A (Heat Dissipation: 761 BTU)

G20X: 140W, 48V, 2.9A (Heat Dissipation: 478 BTU)

10G6X: 230W, 48V, 4.8A (Heat Dissipation: 785 BTU)

10G2X: 145W, 48V, 3.0A (Heat Dissipation: 495 BTU)

10G2H: 223W, 48V, 4.7A (Heat Dissipation: 761 BTU) Fully Loaded System (Chassis + 2 x MSM + 8 x 10G6X): 2760W (Heat Dissipation: 9,421 BTU)

Operating Specifications

Operating Temperature Range: 0° to 40° C

Storage Temperature: -40° to 70° C

Operating Humidity Range: 10% to 95% relative humidity, non-condensing EN60068 to Extreme IEC68 schedule

Regulatory/Safety

Safety Standards

 

UL 1950 3rd Edition 2/93, (U.S. Safety of ITE)

 

cULus Listed Equivalent to CAN/CSA-22.2

No. 950-M93 (Canadian Safety of ITE)

 

Low Voltage Directive (LVD) (European Safety Directive)

CB Report and Certificate (International Safety of ITE)

 

IEC60950:1991/A1-4 2nd Edition (European Safety of ITE)

TUV GS Mark (German Notified Body)

EN60950:1992/A1-4,A11+ Deviations (European Safety of ITE)

 

S/NZS 3260 (Australia Safety Standard)

 

S Mark (Argentina Safety Approval)

GOST (Russian Federation Certificate) Laser Devices

EN60825-1,2:1994, A11:1996 (European Safety of Lasers Products) FCC 21 CFR Subpart J (U.S. Safety of Laser Products)

CDRH Letter of Approval (U.S. FDA Approval)

EMI/EMC Standards

FCC 47 CFR Part 15 Class A (U.S. Emissions)

ICES-003 Class A (Canada Emissions)

89/336/EEC EMC Directive (European Requirements)

CISPR22:1997 Class A (International Emissions)

EN55022:1998 Class A (Europe Emissions)

EN55024:1998 includes IEC/EN 61000-2,3,4,5,6,11 (Europe Immunity)

EN 61000-3-2, -3 (Europe Harmonics and Flicker)

AS/NZS 3548 (Australia Emissions)

VCCI Class A (Japan Emissions)

CNS 13438:1997 Class A (Taiwan Emissions)

MIC Mark (Korean Emissions & Immunity Approval)

NOM/NYCE (Mexican Product Safety & EMC Authorities)

Telcordia GR-1089 (Bellcore Emissions & Immunity Standard)

Telecom Standards

EN 300 386-2 v1.1.3 (1997-12) (European Telecom Standard)

Environmental

EN60068 to Extreme IEC68 schedule

ETS 300 019 to Extreme schedule

Telcordia GR-63-Core (Bellcore Environmental & Safety Standard)

Warranty

1-year on Hardware

90-days on Software


 


Ordering Information

Order Number:

Description:

60011

BlackDiamond 10808 10-slot Chassis (Includes Fan Tray)

60020

BlackDiamond 10808/BlackDiamond 8800 700W/1200W 100-240V PSU

60021

BlackDiamond 10808/BlackDiamond 8800 1200W -48V DC PSU

60015

BlackDiamond 10808 Management and Switch Fabric Module

60016

BlackDiamond 10808 Management and Switch Fabric Module 1XL

61010

BlackDiamond 10808 60-port 1000BASE-X SFP (mini-GBIC) Module

61011

BlackDiamond 10808 20-port 1000BASE-X SFP (mini-GBIC) Module

61030

BlackDiamond 10808 60-port 10/100/1000BASE-T RJ-45 Module

61050

BlackDiamond 10808 6-port 10GBASE-X XENPAK Module

61051

BlackDiamond 10808 2-port 10GBASE-X XENPAK Module

61071

BlackDiamond 10808 hybrid module with
- 2-port 10GBASE-X XENPAK
- 20-port 1000BASE-X SFP
- 20-port 10/100/1000BASE-T RJ-45

60012

BlackDiamond 10808 Spare Fan Tray

60013

BlackDiamond 10808 Spare PSU Controller

62001

BlackDiamond 10808 Blank Front Panel

62011

BlackDiamond 10808 Mid Mount Kit

62012

BlackDiamond 10808 Spare Filter 3-pack

62020

BlackDiamond 6808/10808 Cable Management

10110

10 Gigabit Ethernet XENPAK Transceiver, 850nm, up to 300m on multimode fiber, SC connector

10111

10 Gigabit Ethernet XENPAK Transceiver, 1310nm, up to 10km on single-mode fiber, SC connector

10112

10 Gigabit Ethernet XENPAK Transceiver, 1550nm, up to 40km on single-mode fiber, SC connector

10113

10 Gigabit Ethernet XENPAK Transceiver, 1550nm, up to 80km on single-mode fiber, SC connector

10114

10 Gigabit Ethernet WWDM XENPAK Transceiver, 1310nm up to 300m on multi-mode fiber and up to10km on a single-mode fiber, SC connector

10051

Mini-GBIC, SFP, 1000Base-SX, LC connector

10052

Mini-GBIC, SFP, 1000Base-LX, LC connector

10053

Mini-GBIC, SFP, Extra long distance SMF 70 Km/21 dB budget, LC connector